Operating Instructions for Standard HMI Control Panel
39
WARNING: Never use starting fluid.
When the engine is preparing to start, the SR-3
Standard Truck HMI Control Panel will continue
to display the Standard Display as shown in
Figure 21. The preheat buzzer at the unit (located
on the unit Interface Board) sounds during the
engine pre-heat and crank sequence.
Figure 21: Standard Display
Starting the Electric Motor
Units equipped with the Electric Standby option
only
Electric motor starting is automatic in both
Continuous Mode and CYCLE-SENTRY Mode.
The motor will start as required when the unit is
turned on in Standby Mode and standby power is
connected.
CAUTION: The motor may start automatically
any time the unit is turned on.
When the motor is preparing to start, the SR-3
Standard Truck HMI Control Panel will continue
to show the Standard Display as shown in Figure
22. The preheat buzzer at the unit (located on the
unit Interface Board) sounds for 20 seconds
before the electric motor starts.
Figure 22: Standard Display
Switching from Diesel to
Electric
IMPORTANT: Applies to units with the Electric
Standby Option only. The operation of this
feature can be changed using the Guarded
Access Menu. See the Guarded Access / Unit
Configuration Menu / Diesel to Electric Auto
Switch Enabled feature in Section 3 of the
Diagnostic Manual for details. The Diesel to
Electric Auto Switch Enabled feature should be
set YES on units equipped with the Standard
Truck HMI Control panel.
Diesel to Electric Auto Switch Enabled set YES
(Default):
If this feature is set YES, the unit will
switch automatically from Diesel Mode to
Electric Mode when standby power is connected
and present.
Diesel to Electric Auto Switch Enabled set NO:
The Diesel to Electric Auto Switch Enabled
feature should not be set NO on units equipped
with the Standard Truck HMI Control panel.
Switching from Electric to
Diesel
IMPORTANT: Applies to units with the Electric
Standby Option only. The operation of this
feature can be changed using the Guarded
Access Menu. See the Guarded Access / Unit
Configuration Menu / Electric to Diesel Auto
Switch Enabled feature in the Diagnostic
Manual.
Electric to Diesel Auto Switch Enabled feature set
YES:
If this feature is set YES, the unit will switch
automatically from Electric Mode to Diesel Mode
when standby power is removed or fails.
Electric to Diesel Auto Switch Enabled feature set
NO (Default) :
If the unit is operating in Electric
Mode and standby power is disconnected or fails,
the unit will not automatically switch to Diesel
mode. This is primarily designed to prevent
unauthorized diesel engine starts when the truck is
indoors or on a ferry where engine operation is
strictly prohibited.
If the unit is operating in Electric Mode and
standby power is disconnected or fails, Alarm
Code 91 Check Electric Ready Input will be set.
The red LED between the ON key and OFF Key
Summary of Contents for T-1080S
Page 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Page 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Page 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Page 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Page 186: ...185 Wiring Diagram Page 1 of 5 ...
Page 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Page 188: ...187 Wiring Diagram Page 3 of 5 ...
Page 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Page 190: ...189 Wiring Diagram Page 5 of 5 ...