Refrigeration Service Procedures
134
5. Pressurize the system and test for refrigerant
leaks.
6. If no leaks are found, replace the liquid line
drier then evacuate the system.
7. Replace the compressor/electric motor belt
and adjust the tension.
8. Recharge the unit with the proper refrigerant.
9. Operate the unit at least 30 minutes and then
inspect the oil level in the compressor. Add or
remove oil if necessary.
10. Check the refrigerant charge and add
refrigerant if needed.