3. Using no lubricants, set the coupling on the
crankshaft and align the keyways using the
Keyway Tool (P/N 204-972). Insert the
tapered end of the tool into the keyway and
gently move the coupling on the shaft while
pressing the tool into the keyway. This will
align the keyway in the crankshaft with the
keyway in the coupler.
Figure 54: Keyway Tool P/N 204-972
4. Remove the Keyway Tool and check the fit of
the key (P/N 55-9024). It should fit into the
keyway with a light press fit requiring only a
minimum of light tapping. If the key does not
fit properly, remove the coupler and inspect
the keyways and key for burrs or other
problems. Recheck the fit as shown above.
5. When the key fits properly, remove the
coupling and key from the shaft.
6. Re-install the coupling and align the keyways
with the Keyway Tool.
7. Do not install the key at this time. Install the
flat washer and bolt and pre-torque to 20 ft-lb
(27 N•m). Remove the bolt and washer.
8. Install the key in the keyway. As above, it
should fit with a light press fit requiring only a
minimum of light tapping. Do not install the
key into the keyway beyond the front face
of the coupling. If tapped in farther it may
cause the coupling to move off center on the
shaft.
9. Re-install the bolt and heavy flat washer and
snug the bolt down by hand. Torque the bolt to
90 ft-lb (122 N•m).
10. Spray a corrosion inhibitor (such as spray
paint) on the exposed part of the shaft and the
joint between the shaft and the coupling. This
prevents moisture from wicking into the joint
and causing corrosion.
Condenser Coil
Removal
1. Recover the refrigerant charge.
2. Drain engine coolant from the expansion tank.
Unbolt and remove the coolant expansion tank
from the condenser coil frame. Unsolder the
tank breather tube.
CAUTION: If you are assembling a used
coupler or crankshaft and the tool does
not fit easily there is a problem with one of
the keyways! Do not remove the coupler
and place the key in the crankshaft
keyway and then drop the coupler on. If
the tool does not fit, the key will not fit,
and it will hold the taper in the coupler off
the taper on the shaft. Check both keyways
for burrs or corrosion. A key can be
coated with fine lapping compound and
used as a lapping tool to clean the
keyways.
AGA333
1.
Compressor Coupling or Clutch
2.
Key tapped flush with outside face of coupling.
Do not tap key any farther into keyway.
3.
Torque bolt to 90 ft-lb (122 N•m)
4.
Washer
5.
Spray this area with corrosion inhibitor after
assembling.
Figure 55: Compressor Coupling Installation
1
2
3
4
5
AGA1254
Summary of Contents for Spectrum DE 30-2
Page 4: ...4...
Page 12: ...Safety Precautions 12...
Page 16: ...Specifications 16...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Page 42: ...Operating Instructions 42...
Page 48: ...Electrical Maintenance 48...
Page 106: ...Structural Maintenance 106...
Page 110: ...Mechanical Diagnosis 110...
Page 114: ...Remote Evaporator Specifications 114...
Page 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Page 122: ...Remote Evaporator Electrical Maintenance 122...
Page 126: ...Remote Evaporator Refrigeration Service Operations 126...
Page 128: ...Remote Evaporator Structural Maintenance 128...
Page 130: ...Remote Evaporator System Diagnosis 130...
Page 134: ...Wiring and Schematic Diagrams Index 134...
Page 135: ...135 Schematic Diagram Page 1 of 2...
Page 136: ...136 Schematic Diagram Page 2 of 2...
Page 137: ...137 Wiring Diagram Page 1 of 4...
Page 138: ...138 Wiring Diagram Page 2 of 4...
Page 139: ...139 Wiring Diagram Page 3 of 4...
Page 140: ...140 Wiring Diagram Page 4 of 4...