113
Remote Evaporator Specifications
Refrigeration System
Evaporator Coil Type
Direct Expansion
Refrigerant Type
R-404A
Heat/Defrost Method
Hot Gas
Electrical
Control System Voltage
12.5 Vdc
Circuit Breaker CB1—Zone 3 Fan Motors
30 amp, auto reset
Fuse F12—Zone 3 Fan Motors
25 amp
Fuse F13—Zone 3 Solenoids
15 amp
Fan Motors (each):
Power Rating
0.13 hp (100 Watts)
rpm
2390
Full Load Amps
7 amps (per motor)
Remote Liquid Line Solenoid:
Current Draw
1.3 amps
Resistance
9.6 ohms
Remote Hot Gas Solenoid:
Current Draw
1.5 amps
Resistance
8.3 ohms
Remote Suction Line Solenoid:
Current Draw
1.5 amps
Resistance
8.3 ohms
Summary of Contents for Spectrum DE 30-2
Page 4: ...4...
Page 12: ...Safety Precautions 12...
Page 16: ...Specifications 16...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Page 42: ...Operating Instructions 42...
Page 48: ...Electrical Maintenance 48...
Page 106: ...Structural Maintenance 106...
Page 110: ...Mechanical Diagnosis 110...
Page 114: ...Remote Evaporator Specifications 114...
Page 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Page 122: ...Remote Evaporator Electrical Maintenance 122...
Page 126: ...Remote Evaporator Refrigeration Service Operations 126...
Page 128: ...Remote Evaporator Structural Maintenance 128...
Page 130: ...Remote Evaporator System Diagnosis 130...
Page 134: ...Wiring and Schematic Diagrams Index 134...
Page 135: ...135 Schematic Diagram Page 1 of 2...
Page 136: ...136 Schematic Diagram Page 2 of 2...
Page 137: ...137 Wiring Diagram Page 1 of 4...
Page 138: ...138 Wiring Diagram Page 2 of 4...
Page 139: ...139 Wiring Diagram Page 3 of 4...
Page 140: ...140 Wiring Diagram Page 4 of 4...