Refrigeration Service Operations (Rev. 04/02)
70
3.
Solder the liquid inlet and the suction outlet line con-
nections on the condenser side of the bulkhead. Seal the
openings through the bulkhead with putty when the
refrigerant lines have cooled off.
4.
Solder the suction line connection to the evaporator
coil.
5.
Connect the equalizer line to the suction line and the
liquid outlet line to the expansion valve.
6.
Pressurize the low side and test for leaks. If no leaks are
found, evacuate the low side.
7.
Tighten the heat exchanger mounting hardware
securely.
8.
Clean the suction tube to a brightly polished condition.
Install the feeler bulb clamps and the feeler bulb on the
side of the suction line in its former position. The feeler
bulb must make good contact with the suction line or
the operation will be faulty. Wrap with insulating tape.
9.
Replace the upper and lower evaporator access panels.
10. Open the refrigeration valves and place the unit in oper-
ation.
EVAPORATOR COIL
Removal
1.
Pump down the low side and equalize the pressure to
slightly positive.
2.
Remove the upper and lower rear access panels.
3.
Remove the roadside and curbside evaporator access
panel mounting channels.
4.
Disconnect the sensors.
5.
Remove the feeler bulb from the suction line clamp.
Note the position of the feeler bulb on the suction line.
6.
Unsolder the distributor from the expansion valve.
7.
Unsolder the hot gas line and the suction line from the
evaporator coil.
8.
Remove the mounting bolts, lift and slide the coil from
the housing.
Installation
1.
Place the evaporator coil in the evaporator housing and
install the mounting bolts.
2.
Solder the hot gas line and suction line connections to
the evaporator coil.
3.
Connect the distributor to the expansion valve.
4.
Replace and connect the sensors.
5.
Pressurize the low side and test for leaks. If no leaks are
found, evacuate the low side.
6.
Clean the suction line to a bright polished condition.
Install the feeler bulb on the side of the suction line in
its former position. The feeler bulb must make good
contact with the suction line or operation will be faulty.
Wrap with insulating tape.
7.
Replace the roadside and curbside evaporator access
panel mounting channels.
8.
Replace the upper and lower rear access panels.
9.
Open the refrigeration valves and place the unit in oper-
ation. Check the refrigerant charge and compressor oil.
Add as required.
ACCUMULATOR
Removal
1.
Pump down the low side and equalize the pressure to
slightly positive.
2.
If applicable, disconnect the water lines from the accu-
mulator.
Summary of Contents for SB-III 30 SR+
Page 4: ......
Page 8: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 24: ...Unit Description Rev 04 02 14 Unit Photos Front View AGA231 ...
Page 28: ...18 ...
Page 66: ...56 ...
Page 98: ...88 ...
Page 110: ...100 ...
Page 111: ...101 Early Model Coiled Wire Fuse Link Wiring Schematic ...
Page 112: ...102 Early Model Coiled Wire Fuse Link Wiring Diagram Page 1 of 4 ...
Page 113: ...103 Early Model Coiled Wire Fuse Link Wiring Diagram Page 2 of 4 ...
Page 114: ...104 Early Model Coiled Wire Fuse Link Wiring Diagram Page 3 of 4 ...
Page 115: ...105 Early Model Coiled Wire Fuse Link Wiring Diagram Page 4 of 4 ...
Page 116: ...106 Late Model Fuse Link in Battery Cable Wiring Schematic ...
Page 117: ...107 Late Model Fuse Link in Battery Cable Wiring Diagram Page 1 of 4 ...
Page 118: ...108 Late Model Fuse Link in Battery Cable Wiring Diagram Page 2 of 4 ...
Page 119: ...109 Late Model Fuse Link in Battery Cable Wiring Diagram Page 3 of 4 ...
Page 120: ...110 Late Model Fuse Link in Battery Cable Wiring Diagram Page 4 of 4 ...