Unit Description (Rev. 04/02)
9
Operating Modes
The microprocessor uses a complex program to determine
which operating mode the unit should be in. Therefore, it is
difficult to predict which operating mode the unit should be
in by comparing the setpoint to the box temperature. Also,
the different versions of software that are used have some
operational differences.
The diesel engine operates at either low speed or high speed
as determined by the microprocessor. The unit will cool or
heat in either high or low speed. The unit will defrost in low
speed only. Heat and defrost consists of hot gas delivered to
the evaporator coil distributor.
The unit will operate in either the Fresh or Frozen range
(formerly referred to as “Heat Lockout”). The Fresh-Frozen
range transition point is programmable to either 24 F (-4 C)
or 15 F (-9 C). The operation modes shown below utilize
this range as programmed.
Continuous Mode, Setpoint at or Above
Fresh-Frozen Range
Operating mode is controlled by the microprocessor. When
the temperature is within a few degrees of setpoint, the tem-
perature is considered to be in range and the in-range icon
will turn on. The microprocessor will select the operating
mode from the list of possible modes below:
•
High Speed Cool
•
Low Speed Cool
•
Low Speed Modulated Cool (Optional)
•
Low Speed Modulated Heat (Optional)
•
Low Speed Heat
•
High Speed Heat
•
Defrost
CYCLE-SENTRY Mode, Setpoint at or Above
Fresh-Frozen Range
Operating mode is controlled by the microprocessor. When
the temperature is within a few degrees of setpoint, the tem-
perature is considered to be in range and the in-range icon
will turn on. The microprocessor will select the operating
mode from the list of possible modes below:
•
High Speed Cool
•
Low Speed Cool
•
Null (if engine temperature and battery are satisfied)
•
Low Speed Heat
•
High Speed Heat
•
Defrost
Continuous Mode, Setpoint Below Fresh-Frozen
Range
Operating mode is controlled by the microprocessor. When
the temperature is within a few degrees of setpoint, the tem-
perature is considered to be in range and the in-range icon
will turn on. The microprocessor will select the operating
mode from the list of possible modes below:
•
High Speed Cool
•
Low Speed Cool
•
Low Speed Heat
•
Defrost
Summary of Contents for SB-III 30 SR+
Page 4: ......
Page 8: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 24: ...Unit Description Rev 04 02 14 Unit Photos Front View AGA231 ...
Page 28: ...18 ...
Page 66: ...56 ...
Page 98: ...88 ...
Page 110: ...100 ...
Page 111: ...101 Early Model Coiled Wire Fuse Link Wiring Schematic ...
Page 112: ...102 Early Model Coiled Wire Fuse Link Wiring Diagram Page 1 of 4 ...
Page 113: ...103 Early Model Coiled Wire Fuse Link Wiring Diagram Page 2 of 4 ...
Page 114: ...104 Early Model Coiled Wire Fuse Link Wiring Diagram Page 3 of 4 ...
Page 115: ...105 Early Model Coiled Wire Fuse Link Wiring Diagram Page 4 of 4 ...
Page 116: ...106 Late Model Fuse Link in Battery Cable Wiring Schematic ...
Page 117: ...107 Late Model Fuse Link in Battery Cable Wiring Diagram Page 1 of 4 ...
Page 118: ...108 Late Model Fuse Link in Battery Cable Wiring Diagram Page 2 of 4 ...
Page 119: ...109 Late Model Fuse Link in Battery Cable Wiring Diagram Page 3 of 4 ...
Page 120: ...110 Late Model Fuse Link in Battery Cable Wiring Diagram Page 4 of 4 ...