Electrical Maintenance (Rev. 04/02)
27
The voltage at the B+ terminal should be 13 to 18 volts
and the amperage in the 2A wire should be at least as
high as the rated output of the alternator.
NOTE: An alternator can easily exceed its rated out-
put. An alternator MUST at least reach its rated out-
put when full fielded. An alternator that has a
defective rectifier diode may reach 75% of its rated
output with a full field.
14. Stop the unit.
15. Use the readings obtained previously to determine the
problem by referring to the Diagnosis Chart.
NOTE: This assumes that the alternator did not
charge properly prior to the full field test.
Field Current Test (Checks the field windings,
brushes and slip rings)
Perform this test with the On-Off switch in the OFF posi-
tion.
1.
Attach a clamp-on ammeter to the 2A wire near the B+
terminal on the alternator.
Diagnosis Chart
Amperage in 2A
Voltage at B+
Problem/Solution
At or above rated output
At or above battery voltage and
increasing
Voltage regulator defective / Replace volt-
age regulator and brush assembly
Approximately 60% of
rated output
Approximately equal to battery voltage
and does not change, or rises slightly
Receiver diode defective / Repair or
replace alternator
Low or no output
Less than or equal to battery voltage
and decreasing
Stator windings, field windings, brush or
diode defective / Perform Field Current Test
to check brushes and field coil, or replace
alternator
2.
Connect a jumper wire between the F2 terminal on the
alternator and a chassis ground, and note the ammeter
reading.
3.
The ammeter reading indicates field current. The fol-
lowing chart shows the field current for each alternator
with 12 volts applied to the field:
a.
No field current or a low field current indicates an
open circuit or excessive resistance in the field cir-
cuit. Replace the voltage regulator and brush
assembly, inspect the slip rings and repeat the test.
If the brushes are not the problem, replace the rotor
or the alternator.
b.
High field current indicates a short in the field cir-
cuit. Repair or replace the alternator.
Alternator Rating
Field Current
@ 12 Volts
23 Amp
1.0 to 3.0 Amps
37 Amp
3.5 to 4.5 Amps
65 Amp
4.0 to 5.0 Amps
Summary of Contents for SB-III 30 SR+
Page 4: ......
Page 8: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 24: ...Unit Description Rev 04 02 14 Unit Photos Front View AGA231 ...
Page 28: ...18 ...
Page 66: ...56 ...
Page 98: ...88 ...
Page 110: ...100 ...
Page 111: ...101 Early Model Coiled Wire Fuse Link Wiring Schematic ...
Page 112: ...102 Early Model Coiled Wire Fuse Link Wiring Diagram Page 1 of 4 ...
Page 113: ...103 Early Model Coiled Wire Fuse Link Wiring Diagram Page 2 of 4 ...
Page 114: ...104 Early Model Coiled Wire Fuse Link Wiring Diagram Page 3 of 4 ...
Page 115: ...105 Early Model Coiled Wire Fuse Link Wiring Diagram Page 4 of 4 ...
Page 116: ...106 Late Model Fuse Link in Battery Cable Wiring Schematic ...
Page 117: ...107 Late Model Fuse Link in Battery Cable Wiring Diagram Page 1 of 4 ...
Page 118: ...108 Late Model Fuse Link in Battery Cable Wiring Diagram Page 2 of 4 ...
Page 119: ...109 Late Model Fuse Link in Battery Cable Wiring Diagram Page 3 of 4 ...
Page 120: ...110 Late Model Fuse Link in Battery Cable Wiring Diagram Page 4 of 4 ...