Structural Maintenance (Rev. 12/03)
84
DEFROST DAMPER
Check the damper during scheduled maintenance inspec-
tions for shaft wear, end play, and the ability to stop the air
flow.
Position the damper so that air flow is stopped on the top
and bottom edges with the solenoid plunger bottomed out.
To adjust the damper:
1.
Remove the damper assembly from the evaporator.
2.
Disconnect the damper link from the eye bolt.
AEA719
1.
Stop
6.
Eye Bolt
2.
Mounting Bolts
7.
Round Stop
3.
Closed Position
8.
Distance A 2.75 in. (69.85 mm)
4.
Open Position
9.
Solenoid
5.
Damper Link
Defrost Damper Adjustment
1
2
9
8
1
7
4
3
5
6