8
PRELIMINARY CHECKS
Carefully remove the packing and check that the product is complete and undamaged. If any defect or damage is de-
tected, do not install or attempt to repair the product but return it to the retailer. Dispose of packaging in compliance with
applicable law.
b
Make sure that the installation position provides easy visibility of and access to the safety valves.
b
Connect the safety valves to a drain in conformity to applicable standards.
b
Install the product as near as practical to the storage cylinder. The product is designed to work with a pipe length
of 4 metres (inlet and return) between itself and the storage cylinder.
b
Disconnect the product from the mains power supply before commencing any work on it.
b
The product must be installed in conformity to the laws and standards applicable in the country of installation.
b
The manufacturer’s responsibility ends with the supply of the product. The product must be installed in conformity
to applicable standards by suitably qualified persons employed by a company that assumes full responsibility for
the completed installation.
INSTALLATION AND PUTTING INTO SERVICE
Bear in mind the following before installing the product:
- The product is designed to mix domestic hot water from a storage cylinder. Any other use, or any use incompatible with
the product’s technical specifications, is considered improper. Do not connect the product directly to a boiler.
- The product is not designed to be operated by children or persons with limited physical, psychological, sensorial or
mental capacities.
- If the piping needed to connect the product to the water system is damaged, it must be replaced by a suitably qualified
person.
- The installation must comply with all applicable laws and standards.
SYSTEM SCHEMATIC
INSTALLATION
Example of wall mounted installation
Boiler
DHW outlet
Recirculation
Cold water inlet
Primary outlet (return)
Primary inlet
Summary of Contents for MODEX ACS 40 E