12
ENGLISH
GENERAL
LOCATION OF SENSORS
Characteristics of boiler, flow and storage cylinder sensors
Measured temperature (°C) - Resistance (
Ω
).
T (°C)
R (Ω)
T (°C)
R (Ω)
T (°C)
R (Ω)
T (°C)
R (Ω)
-30.0
175203
30.0
8059
90.0
915
150.0
183
-25.0
129289
35.0
6535
95.0
786
155.0
163
-20.0
96360
40.0
5330
100.0
677
160.0
145
-15.0
72502
45.0
4372
105.0
586
165.0
130
-10.0
55047
50.0
3605
110.0
508
170.0
117
-5.0
42158
55.0
2989
115.0
443
175.0
105
0.0
32555
60.0
2490
120.0
387
180.0
95
5.0
25339
65.0
2084
125.0
339
185.0
85
10.0
19873
70.0
1753
130.0
298
190.0
77
15.0
15699
75.0
1481
135.0
262
195.0
70
20.0
12488
80.0
1256
140.0
232
200.0
64
25.0
10000
85.0
1070
145.0
206
THC V 35 E OIL BLU
1 - Boiler temperature sensor
2 - Safety thermostat sensor
3 - Flue gas thermostat sensor
THC V 55 E OIL BLU
1 - Boiler temperature sensor
2 - Safety thermostat sensor
3 - Flue gas thermostat sensor
1
2
3
3
1
2