The maximum flow rates are only recommended flow rates to minimize scale formation and to reduce 
wear on the elements. The heater is fitted with a pressure relief valve set to lift at 2 Bar (29 psi). Maximum 
flow rates throughout your system will depend on your system configuration. 

 

 
Flow Rate 

 

 

3 kW 

 

4 kW 

 

6kW 

 

7.5 kW 

Hard water maximum 
 - use bypass above this rate 
 - minimise scale formation 
 

 

2000 gal/hr 

152 l/min 

 

2000 gal/hr 

152 l/min 

 

2000 gal/hr 

152 l/min 

 

2000 gal/hr 

152 l/min 

Soft water maximum 
 - use bypass above this rate 
 - improves element life 
 

 

1000 gal/hr 

76 l/min 

 

1000 gal/hr 

76 l/min

 

 

1000 gal/hr 

76 l/min

 

 

1000 gal/hr 

76 l/min

 

 
Minimum 

60 gal/hr 

4.5 l/min 

 

80 gal/hr 

6 l/min 

120 gal/hr 

9 l/min 

150 gal/hr 

11 l/min 

 

 

 

 

 

 

 

 

 
Flow Rate 

 

 

9 kW 

 

10 kW 

 

12 kW 

Hard water maximum 
 - use bypass above this rate 
 - minimise scale formation 
 

 

2000 gal/hr 

152 l/min 

 

2000 gal/hr 

152 l/min 

 

2000 gal/hr 

152 l/min 

Soft water maximum 
 - use bypass above this rate 
 - improves element life 
 

 

1000 gal/hr 

76 l/min 

 

1000 gal/hr 

76 l/min 

 

1000 gal/hr 

76 l/min 

 
Minimum 

180 gal/hr 

15 l/min 

200 gal/hr 

16 l/min 

 

240 gal/hr 

20 l/min 

Fig 2. 

 

  DRAINAGE: A method of draining water away from the heater and other equipment is provided. The 
heater should be flushed at the end of each swimming season. During flushing or servicing, water may be 
spilled and could cause damage to the floor or other equipment. A drain valve has been fitted to the 
vessel to aid you. 

Flow direction through the heater is left to right, allowing the temperature controller to sense the 
temperature coming from the pool.  The direction may be changed by reversing the probes of the control 
thermostat and the safety thermostat, as follows: 

 

 

a) 

Switch heater circuit breakers to OFF; 

b) 

Switch main power supply and pump interlock supply to OFF; 

c) 

Remove main cover; 

Summary of Contents for 120THR

Page 1: ...Check all electrical connections to all components within the heater for tightness Connections can become loose during shipment and handling this can cause electrical components to burn out CAUTION Th...

Page 2: ...may lead to unconsciousness with the possibility of drowning e Obese persons and persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes shou...

Page 3: ...eater selection installation and operation This is particularly for difficult applications such as sea water pools health spas or hydrotherapy pools areas in which the performance of Thermalec pool he...

Page 4: ...cut off the power in the event of excessive temperature A pump interlock switch is built in to prevent the pool heater from operating without the pump being energized we use this because we have foun...

Page 5: ...not heat properly unless it is plumbed correctly If plastic pipe is used it should be suitable for at least 49 C 120 F A plumbing bypass around the pool heater is not necessary unless flow rate thoug...

Page 6: ...minimise scale formation 2000 gal hr 152 l min 2000 gal hr 152 l min 2000 gal hr 152 l min Soft water maximum use bypass above this rate improves element life 1000 gal hr 76 l min 1000 gal hr 76 l mi...

Page 7: ...during shipment and handling c Check components for any moisture rust or dust which may have accumulated during shipping and clean or dry where necessary All pool heaters covered in this manual have i...

Page 8: ...he heater cover and the plastic terminal cover Single phase All 12THR heaters are delivered configured for single phase operation It is vital that all wires are firmly terminated into the appropriate...

Page 9: ...her control the operation of the heater A time switch can be fitted to interrupt the supply to terminal A ensuring that it can only come on during specific periods of cheap electricity This is detaile...

Page 10: ...affected area Pool Not Reaching Desired Temperature If the status lamps are lit as described on the previous page and the contactors can be heard engaging then the heater can be said to be operating c...