Rio Grande RF

 

I M P O R TA N T   -   S AV E   T H E S E  

I N S T R U C T I O N S   F O R   F U T U R E   R E F E R E N C E  

Reference Manual 

 

Rio Grande RF 

 

EUROPEAN MODEL HEATERS: 

 

GRAS-015RF-HW           (230V / 1.5kW) 
GRAS-020RF-HW           (230V / 2.0kW) 

Spectrum House, Unit 1, Ridgacre Road, West Bromwich, 

West Midlands, B71 1BW, England 

Tel: +44 (0)121 580 6200   -   Fax: +44 (0)121 580 6222 

Email: [email protected]   -   Website: www.tansun.com 

IPX4 

Summary of Contents for Rio Grande RF GRAS-015RF-HW

Page 1: ...ve the right to make changes without notice 2017 TANSUN LIMITED Ref No 043262 Issue No A Rio Grande RF IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Reference Manual Rio Grande RF EUROPEAN MODEL HEATERS GRAS 015RF HW 230V 1 5kW GRAS 020RF HW 230V 2 0kW Spectrum House Unit 1 Ridgacre Road West Bromwich West Midlands B71 1BW England Tel 44 0 121 580 6200 Fax 44 0 121 580 6222 Email sales ta...

Page 2: ...aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of the product can become very hot and cause burns Particular attention has been given where children and vulnerable people are present Remove the plug from the mains socket or disconnect pole switch during installation cleaning and or replacing the element and ...

Page 3: ...ord may overheat and cause a risk of fire Keep the mains supply cord away from the body of the heater which will get hot during use Arrange the mains supply cord so it cannot be tripped over or damaged Do not cover or obstruct the heater while it is in use Do not insert any object through any slot or opening in the heater Do not use if a guard is not present Do not install less than the minimum mo...

Page 4: ...ces If the supply cord becomes damaged it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard If in any doubt please contact a suitably qualified electrician Model GRAS 015RF GRAS 020RF Voltage V 230V Power kW 1 5kW 2 0kW Current A 6 5A 8 7A Min height from floor 2 0m Min distance from ceiling 0 3m Min distance from side wall 1 0m Dimensi...

Page 5: ... and less than 30 from the mounting surface as shown in Fig A Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on Observe the minimum safe distance between the heater body and inflammable surfaces and objects when mounting Please refer to Table 1 for the recommended positioning of the heater Do not install the heater in a co...

Page 6: ... lamps quartz glass causing premature failure YOUR REPLACEMENT EMITTER LAMP It is very important that your replacement emitter lamp is exactly the same as the one it was supplied with Failure to fit the exact same type could cause the heater to fail or even become dangerous especially when used in an outdoor environment Please contact your distributor to purchase your replacement emitter lamp and ...