CUTMASTER 60i
INTRODUCTION
Manual 0-5436
2-4
21.121"
536.47 mm
35 lb / 15.875 kg
7.847
199.3 mm
14.146"
359.3 mm
Art # A-13252
15"
381 mm
6"
150 mm
15"
381 mm
6"
150 mm
Art # A-13247
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
2.05 Input Wiring Specifications
WARNING
Each CutMaster 60i system is a dedicated 1 Phase OR 3 Phase
system and cannot be reconfigured to the other. Personal injury
could occur if changing the phase is attempted..
1 Phase
1 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I
1
eff
Fuse (amps)
Flexible Cord (Min.
AWG)
1 Phase
208
50/60
8.9
43
30.5
50
8 AWG (10mm
2
)
230
50/60
8.9
38.9
27.6
50
10 AWG (10mm
2
)
380
50/60
8.9
23.5
16.7
30
12 AWG (2.5mm
2
)
400
50/60
8.9
22.4
15.9
30
14 AWG (2.5mm
2
)
415
50/60
8.9
21.6
15.3
30
14 AWG (2.5mm
2
)
480
50/60
8.9
18.6
13.2
30
14 AWG (2.5mm
2
)
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
Single Phase
Summary of Contents for CUTMASTER 60i
Page 6: ...This Page Intentionally Blank ...
Page 16: ...CUTMASTER 60i GENERAL INFORMATION Manual 0 5436 1 8 This Page Intentionally Blank ...
Page 22: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2 6 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2T 4 This Page Intentionally Blank ...
Page 34: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3 8 This Page Intentionally Blank ...
Page 36: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3T 2 This Page Intentionally Blank ...
Page 44: ...CUTMASTER 60i OPERATION Manual 0 5436 4 8 This Page Intentionally Blank ...
Page 72: ...CUTMASTER 60i SERVICE Manual 0 5436 5 12 This Page Intentionally Blank ...
Page 89: ...This Page Intentionally Blank ...