CUTMASTER 60i
Manual 0-5436
OPERATION
4T-11
CutMaster® 60i With Exposed Tip
Type Material: Stainless Steel
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output Amperage
Speed (Per
Minute)
Standoff
Plasma Gas
Pressure*
Flow (SCFH)
Pierce
Pierce
Height
Inches
mm
(Cat. No.)
Volts
(VDC)
(Amps)
Inches Meters
Inches
mm
psi
bar
Plasma Total**
Delay
(Sec)
Inches mm
0.06
1.5
9-8210
119
60
350
8.91
0.19
4.8
Set to the
central
region on
the pressure
dial. This is
illuminated
green when
selected.
90
245
0.00
0.20
5.1
0.075
1.9
9-8210
116
60
300
7.64
0.19
4.8
90
245
0.10
0.20
5.1
0.120
3.0
9-8210
123
60
150
3.82
0.19
4.8
90
245
0.10
0.20
5.1
0.135
3.4
9-8210
118
60
125
3.18
0.19
4.8
90
245
0.10
0.20
5.1
0.188
4.8
9-8210
122
60
90
2.29
0.19
4.8
90
245
0.20
0.20
5.1
0.250
6.4
9-8210
120
60
65
1.65
0.19
4.8
90
245
0.30
0.20
5.1
0.375
9.5
9-8210
130
60
30
0.76
0.19
4.8
90
245
0.50
0.20
5.1
0.500
12.7
9-8210
132
60
21
0.53
0.19
4.8
90
245
0.75
0.20
5.1
0.625
15.9
9-8210
130
60
15
0.38
0.19
4.8
90
245
Rolling Pierce
0.750
19.1
9-8210
142
60
12
0.31
0.25
6.4
90
245
Rolling Pierce
1.000
25.4
9-8210
NR, manual cutting only
90
245
Rolling Pierce
1.250
31.8
9-8210
NR, manual cutting only
90
245
NR
CutMaster® 60i With Exposed Tip
Type Material: Aluminum
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output Amperage
Speed (Per
Minute)
Standoff
Plasma Gas
Pressure*
Flow (SCFH)
Pierce
Pierce
Height
Inches
mm
(Cat.
No.)
Volts
(VDC)
(Amps)
Inches Meters Inches
mm
psi
bar
Plasma Total**
Delay
(Sec)
Inches
mm
0.060
1.5
9-8210
110
60
440
11.18
0.25
6.4
Set to the
central
region on
the pressure
dial. This is
illuminated
green when
selected.
90
245
0.00
0.25
6.4
0.075
1.9
9-8210
110
60
440
11.18
0.25
6.4
90
245
0.10
0.25
6.4
0.120
3.0
9-8210
116
60
250
6.35
0.25
6.4
90
245
0.10
0.25
6.4
0.188
3.4
9-8210
116
60
170
4.32
0.25
6.4
90
245
0.20
0.25
6.4
0.250
6.4
9-8210
132
60
85
2.16
0.25
6.4
90
245
0.30
0.25
6.4
0.375
9.5
9-8210
140
60
45
1.14
0.25
6.4
90
245
0.50
0.25
6.4
0.500
12.7
9-8210
143
60
30
0.76
0.25
6.4
90
245
0.80
0.25
6.4
0.625
15.9
9-8210
145
60
20
0.51
0.25
6.4
90
245
Rolling Pierce
0.750
19.1
9-8210
145
60
18
0.46
0.25
6.4
90
245
Rolling Pierce
1.000
25.4
9-8210
NR, manual cutting only
90
245
Rolling Pierce
1.250
31.8
9-8210
NR, manual cutting only
90
245
NR
NOTE!
* If the proper torch and lead length are selected using the 'gas pres-
sure selector' knob and the central region (green) on the pressure dial
is selected, the pressure is optimized for the selected
cutting amperage.
Refer to Section 4 of the Operating Manual, "Set Operating Pressure".
** Total flow rate includes plasma and secondary gas flow.
Summary of Contents for CUTMASTER 60i
Page 6: ...This Page Intentionally Blank ...
Page 16: ...CUTMASTER 60i GENERAL INFORMATION Manual 0 5436 1 8 This Page Intentionally Blank ...
Page 22: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2 6 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2T 4 This Page Intentionally Blank ...
Page 34: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3 8 This Page Intentionally Blank ...
Page 36: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3T 2 This Page Intentionally Blank ...
Page 44: ...CUTMASTER 60i OPERATION Manual 0 5436 4 8 This Page Intentionally Blank ...
Page 72: ...CUTMASTER 60i SERVICE Manual 0 5436 5 12 This Page Intentionally Blank ...
Page 89: ...This Page Intentionally Blank ...