CUTMASTER 60i
Manual 0-5436
INTRODUCTION
2-5
3 Phase
3 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I
1
eff
Fuse (amps)
Flexible Cord (Min.
AWG)
3 Phase
208
50/60
9.1
26
18.5
40
12 AWG (2.5mm
2
)
230
50/60
9.1
23.3
16.5
30
12 AWG (2.5mm
2
)
380
50/60
8.9
13.8
9.8
20
14 AWG (2.5mm
2
)
400
50/60
8.9
13.2
9.4
20
14 AWG (2.5mm
2
)
415
50/60
9.1
12.8
9.1
20
16 AWG (1.5mm
2
)
480
50/60
9.2
11.3
8.0
15
16 AWG (1.5mm
2
)
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
Three Phase
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for
proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
2.06 Power Supply Features
Handle and Leads Wrap
Torch Leads Receptacle
Control Panel
Work Lead Receptacle
Art # A-13258
Input Power Cord
Port for Optional Automation
Interface Cable
Gas Inlet Port
Filter Assembly
Input Power ON/OFF Switch
Art # A-13275
Summary of Contents for CUTMASTER 60i
Page 6: ...This Page Intentionally Blank ...
Page 16: ...CUTMASTER 60i GENERAL INFORMATION Manual 0 5436 1 8 This Page Intentionally Blank ...
Page 22: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2 6 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 60i INTRODUCTION Manual 0 5436 2T 4 This Page Intentionally Blank ...
Page 34: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3 8 This Page Intentionally Blank ...
Page 36: ...CUTMASTER 60i INSTALLATION Manual 0 5436 3T 2 This Page Intentionally Blank ...
Page 44: ...CUTMASTER 60i OPERATION Manual 0 5436 4 8 This Page Intentionally Blank ...
Page 72: ...CUTMASTER 60i SERVICE Manual 0 5436 5 12 This Page Intentionally Blank ...
Page 89: ...This Page Intentionally Blank ...