APPENDIX 1: INPUT WIRING REQUIREMENTS
NOTES
The table above is based on the following output current and voltage: 130VDC @ 60A
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Current Input
Suggested Sizes
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
380
50/60
12.4
18.9
25
6
415
50/60
12.6
17.5
25
4
Line Voltages with Recommended Circuit Protection and Wire Sizes
Input
Power Input