Manual 0-2782
4-3
OPERATION
4. Optional Filters
a.
Single-Stage Air Filter Assembly
This in-line filter removes moisture and contaminants
from the air stream when using compressed air. The
filter is capable of filtering to at least 0.85 microns.
1
2
3
4
A-02965
Figure 4-5 Rear Panel Showing Optional Single-
Stage Air Filter
b.
Two Stage Air Line Filter
This optional filter will also remove moisture and con-
taminants from the air stream when using compressed
air. Filters to 5.0 microns.
A-01152
1
3
4
2
Figure 4-6 Rear Panel Showing Optional Two Stage
Air Filter
4.03 Sequence of Operation
The following is a typical sequence of operation for this
cutting system. Refer to Appendix 2 for a block diagram.
1.
Close main power source disconnect.
a. AC power is available at the Power Supply.
2.
Place RUN/SET/LATCH switch to RUN mode.
3.
Place the ON/OFF power switch on the front panel
of the Power Supply to ON.
a. AC Power indicator blinks ON and OFF for
eight seconds then stays ON.
b. Fans turn on.
Summary of Contents for CE PAKMaster 75 XL Plus
Page 2: ......
Page 6: ......
Page 28: ...INSTALLATION 3 12 Manual 0 2782 ...
Page 47: ...Manual 0 2782 A 5 APPENDIX This page left blank ...
Page 48: ...APPENDIX A 6 Manual 0 2782 APPENDIX 5 SYSTEM SCHEMATIC A 02638 ...
Page 49: ...Manual 0 2782 A 7 APPENDIX A 02638 ...
Page 50: ......