Figure 138: Securing Power Supply Wire to Terminal
1 Flat
washer
2 Supply
wire
3 Cupped
wire
4 Upper
nut
NOTE:
It is always recommended to label and tag all wires and
harnesses prior to disconnecting them, so as to correctly identify
their connections/locations when re-assembling. Alternatively, you
can photograph the wire connections prior to disconnecting (for
example, with your mobile phone).
3. Remove and retain the two screws that secure the terminal block
onto the terminal box.
4. When replacing the terminal block, refer to
Connections at the Terminal Block
, page
.
4.6.5 Electrical Wiring Connections at the Terminal Block
The range must be connected to the power supply utilizing either a
three-wire connection, four-wire connection, or a permanent
connection (hard wiring).
For electrical wiring requirements and safety
precautions, refer to the Installation Instructions manual for this
appliance.
NOTE:
The electrical wiring diagram is located on the back side of the
kick panel (see
page 5
4.6.6 Cooling Fan Removal and Replacement
Some models use a cooling fan with a Hall Effect sensor attached,
which is a part of the cooling fan assembly. Other models use a
cooling fan with an air interlock switch installed (see
Switch Removal and Replacement
, page
).
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Sharp Component – Use Gloves
Use gloves when handling the cooling fan, as it has sharp edges
Figure 139: Cooling Fan Showing Mounting Plate and Screw Locations
1
Screw locations (4) securing fan mounting plate onto
range
1. Follow all safety precautions and steps in
2. Remove the backguard, per
Backguard and Island Trim Removal
procedure, page
.
3. Remove back panel, per
Back Panel Removal and Replacement
procedure, page