Note:

 Check local codes for required breaker size

Important:

 Requires a 5" free area between 

the bottom of the cooktop to any combustible 
material, i.e., shelving. Free area not required 
when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires a  
15" minimum from cooktop to adjacent  
overhead cabinets. Units are furnished with  
a 48" flexible armored cable. 

Note:

 36" Ribbon cooktops are approved for use over GE 30" Single Wall 

Ovens and Warming Drawers only. Refer to cooktop and wall oven/ 
warming drawer installation instructions packed with product for  
current dimensional data. If installed with a GE Profile

™ 

Telescopic 

Downdraft System, consult both the cooktop and downdraft installation 
instructions packed with product before installing. Cooktop gas/electric 
supply may need to be re-routed to install downdraft. The countertop  
must be at least 26" deep with a flat surface area of 23-1/2" or more, 
front to back. In addition, other clearances to the front edge of the  
countertop must be considered, especially on raised bullnose countertops. 
Consult cabinet and countertop manufacturer’s specs for flush mount 
installation prior to install.

Installation Information:

 Before installing, consult installation instructions 

packed with product for current dimensional data.

KW Rating

240V

8.9

208V

6.7

Breaker Size

240V

40 Amps

208V

40 Amps

3-1/4*

Cooktop

2-1/2**

Required

33-7/8

19-1/8

36

36_color_cktp_install

20-7/8

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

2" MIN.

clearance to

side wall

from cut-out

2" MIN.

clearance to

side wall

from cut-out

1-3/4" to

rear wall

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/4" on models PP980/975/950/945 and 4-5/8" 

on models PHP960/900, PP972/962/942/932/912 

and JP6SS/356/346/340.

 **Raised bull nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

220592 

Specification Revised 4/09

Dimensions and Installation Information (in inches)

PP975SM 

GE Profile

™ 

36" Built-In CleanDesign Electric Cooktop

 