Service Manual for Thermador Pro Grand Dual Fuel Ranges:
PRD304EG,
PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
58300000157422_ARA_EN_A
Page 21 of 95
4 SERVICE AND REPAIR
4.1 Preparing the Range for Servicing
For most servicing of this appliance (for example, involving
disassembly, or component removal / installation), you will need to do
the following
prior
to starting:
■
Turn off the gas supply to the range by closing the gas valve at
the wall
■
Turn off the electrical power to the range by removing the power
cord from the electrical outlet, and putting the circuit breaker in the
OFF
position (or removing the fuse)
■
Make sure the range components are not hot before servicing
■
Wear protective clothes: long sleeves, gloves, safety glasses
If testing the appliance requires the use of electrical power and/or an
open gas supply, exercise extreme caution.
4.2 Accessing Components under the Maintop
This section contains the steps required to gain access to the
components located under the maintop(s).
4.2.1 Removing Knobs, Grates, Trim, Burner Assemblies
To access and service components located underneath the maintops
(see Figure 11), first remove the knobs, grates, trim, and burner
assemblies. Then remove spilltrays, heat shields, and burner support
rail(s).
1. [Optional – only if a component attached to a knob needs
replacing] Remove knob from valve stem by slowly pulling knob
straight out, away from control panel.
2. Remove all grates.
3. Remove all trim from the maintop (see Figure 24).
Figure 24: Trim
4. Remove all Star burner caps (see Figure 25).
5. Use a 20 mm socket to remove the Venturi tube from the
receptacle in the brass burner base (see Figure 25).
Figure 25: Star Burner Assembly
1 Burner
cap
2
Igniter plug (electrode) – with spring
3
Burner base (brass)
4 Venturi
tube