Figure 81: Solenoid Valve and Respective Fittings for Grill Burner
1
Gas flex tube
2 Compression
nut
3 Sleeve
4
Solenoid valve outlet (to gas flex tube / grill burner)
5 Solenoid
valve
6
Solenoid valve inlet (connected to gas flex tubing
that extends to manifold elbow connector fitting)
4.5.6 XLO Valve Removal and Replacement
The XLO valves are for the left-most front and left-most rear (simmer)
burners only. When replacing the XLO valve, on some models you
may need to remove the potentiometer together with the XLO valve,
while on other models you may snap the potentiometer off the XLO
valve.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 82: Typical XLO Valve
1. Follow all safety precautions and steps in
2. Follow all steps in
Accessing Components under the Maintop
3. Remove knob from valve stem by slowly pulling knob straight out,
away from control panel.
4. If a burner support rail obstructs access to the XLO valve, then
remove the burner support rail (with jet holder assemblies
attached) by following the steps in
page
5. While using a 1/2 inch wrench to hold the nut on the solenoid
valve, unscrew the gas tube hex nut with a 9/16th inch wrench.
Then unscrew the other side of the gas tube attached to the jet
holder assembly and remove the gas tube. Be careful not to bend
the gas tube (see Figure 80, page 43).