EX-TRAFIRE
®
30H
Operator Manual, Revision T-15
4-25
Torch consumables installation
WARNING
Plasma arc is generated immediately
when the torch trigger is depressed
Plasma arc is generated immediately when the torch trigger is depressed�
The plasma arc will cut quickly through gloves and skin� Make sure the power is switched off before
changing consumables�
4� Fit the nozzle on to
the swirl ring�
5� Screw on the nozzle
retaining cap and tighten by
hand� Do NOT overtighten�
2� Insert the swirl ring with beveled edge in the
torch body� Must seated correctly�
3� Perform free movement test of the electrode inside
the swirl ring (by pushing the electrode)�
6� Screw on the hand (contact) shield (tighten by hand)� Do NOT overtighten�
1� Screw the electrode� Use the electrode wrench
(EX-2-427-010)� Do NOT overtighten electrode�
Hand Shield