Open circuit voltage (U
0
)
320 VDC
Output characteristic*
* Curve is defined as the output voltage versus output current
Drooping
Rated output current (I
2
)
10–30 A
standard rated output voltage (
U
2
)
at U
1
= 220 - 240 VAC
92 VDC
standard rated output voltage (U
2
) at duty cycle
X
35%
60%
100%
U
2
92 V
90 V
88�4 V
Cutting current at 35%/60%/100% duty cycle
220 - 240 VAC
30/25/21 A
Maximum input power
220 - 240 VAC
4�9 kVA
Duty cycle (X*) at 40º C at rated conditions (U
1
, I
1
, U
2
, I
2
)
*X=Ton/Tbase,
Ton = time, minutes
Tbase =10 minutes
U
1rms
X
220 - 240 VAC
35%
Operating temperature
−10º – +40º C
Rated AC phases (PH) and line frequency (Hz)
Model CE
PH
Hz
1
50-60
Rated input voltage (U
1
), rated input current (I
1
) and
effective input current (I
1eff
*) at rated output voltage
(U
2
) and rated output current (I
2
) - for cutting only�
* I
1eff
= (I
1
) √X
used to determine rating of power cord�
eff = effective
rms = root mean square
U
1rms
I
1rms
I
1eff
220 - 240 VAC
22*A
13*A
This equipment conforms to IEC 60974-1, IEC 60974-10
Isolation class
F
IP Code – Degree of protection provided by enclosure
IP23S*
IP – “International Protection”
2 – No ingress foreign objects ≥ 12�5 mm
3 – No harmful ingress spraying water�
S – fan stationary during water test�
*
WARNING: ! DO NOT OPERATE IN RAIN !
Toppling, tilting ( with or without Wheel kit)
Up to 15º incline
Gas type
Air
Nitrogen
Gas quality specification
Recommended Air quality:
ISO 8573-1 Class 1�2�2�
Purity ≥ 99�99%
Air max� particle size:
0�1 microns, class 1
ref� to ISO 8573
Air max� oil: 0�1 mg / m3,
class 2 ref�: ISO 8573
Air max� dewpoint: +3° C,
class 4 ref� to ISO 8573
Gas quality
Clean, moisture-free, without oil
Gas input pressure and flow
10 bar/145 psi 48 l/min
Dimensions ( l x h x w ) (mm)
480 x 290 x165
Weight (kg)
10�5
Specifications: Plasma arc power supply
Summary of Contents for EX-TRAFIRE 30H
Page 49: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 49 Notes...
Page 50: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 50 Notes...
Page 51: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 51 Notes...
Page 52: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 52 Notes...
Page 54: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 54 Revision history...