background image

THERAFLO REPLACEMENT PARTS DIAGRAM

THERAFLO REPLACEMENT PARTS TABLE

REF NO.

PART NO.

DESCRIPTION

1 & 2

THERAF4320

Hand Knob Kit for Strainer Cover (inc Hand Knob & 
Swivel Nut)

3

THERAF4304

Strainer Cover, Hand Knob Style - Clear

4

THERAF4303

Strainer Cover O-Ring

5

THERAF4302

Basket

6

THERAF4301B

Pump Housing/Strainer - 50mm, w/Drain Plugs, threaded 
external

7 & 8

THERAF4318

Drain Plug with O-Ring

9

THERAF4317

Mounting Foot Cap Screw (set of 2)

10

THERAF4316B

Mounting Bracket, hps style

11

THERAF4323

Spacer for motor support (required only for 1hp model)

12, 13, 14

THERAF4321

Union Kit (set of 2) suit 40mm & 50mm w/Gasket (T-Seal)

15

THERAF4322

Union Gasket (T-Seal)

16

THERAF4305

Housing Gasket

17

THERAF4323B

Diffuser Gasket

18

THERAF4306C

Diffuser

19

THERAF4307B

Impeller Ring

20

THERAF4308K

Impeller 1HPVS (required only for 1hp model)

21

THERAF4309B

Seal Assembly (inc, Mechanical Seal and Slinger)

22

THERAF4312B

Slinger 

23

THERAF4310B

Seal Plate 

24

THERAF4311B

Motor Cap Screw (4 required)

25

THERAF4313B

Motor Mounting Plate

26

THERAF4315K

Motor 1HPVS (required only for 1hp model)

27

THERAF4314

Housing Cap Screw (6 required)

THERAF4308H

Impeller 1.5HPVS (required only for 1.5hp model)

THERAF4315L

Motor 1.5HPVS (required only for 1.5hp model)

THERAFLO REPLACEMENT PARTS DIAGRAM

THERAFLO REPLACEMENT PARTS TABLE

REF NO.

PART NO.

DESCRIPTION

1 & 2

THERAF4320

Hand Knob Kit for Strainer Cover (inc Hand Knob & 
Swivel Nut)

3

THERAF4304

Strainer Cover, Hand Knob Style - Clear

4

THERAF4303

Strainer Cover O-Ring

5

THERAF4302

Basket

6

THERAF4301B

Pump Housing/Strainer - 50mm, w/Drain Plugs, threaded 
external

7 & 8

THERAF4318

Drain Plug with O-Ring

9

THERAF4317

Mounting Foot Cap Screw (set of 2)

10

THERAF4316B

Mounting Bracket, hps style

11

THERAF4323

Spacer for motor support (required only for 1hp model)

12, 13, 14

THERAF4321

Union Kit (set of 2) suit 40mm & 50mm w/Gasket (T-Seal)

15

THERAF4322

Union Gasket (T-Seal)

16

THERAF4305

Housing Gasket

17

THERAF4323B

Diffuser Gasket

18

THERAF4306C

Diffuser

19

THERAF4307B

Impeller Ring

20

THERAF4308K

Impeller 1HPVS (required only for 1hp model)

21

THERAF4309B

Seal Assembly (inc, Mechanical Seal and Slinger)

22

THERAF4312B

Slinger 

23

THERAF4310B

Seal Plate 

24

THERAF4311B

Motor Cap Screw (4 required)

25

THERAF4313B

Motor Mounting Plate

26

THERAF4315K

Motor 1HPVS (required only for 1hp model)

27

THERAF4314

Housing Cap Screw (6 required)

THERAF4308H

Impeller 1.5HPVS (required only for 1.5hp model)

THERAF4315L

Motor 1.5HPVS (required only for 1.5hp model)

THERAFLO WARRANTY

Theraflo 

S-Sieries

 carries a 3-year limited warranty and is structured in the 

following way:

2 years warranty on motor

1 year warranty on mechanical seal

 

3 years on all other parts

Return to base.

Our warranty covers manufacturing faults, not wear and tear.  We will, at our 

discretion, repair or replace the faulty material or part. It is your responsibility to 

notify Theralux  at  the  earliest  possible  time of  any  issues  found  within  the 

warranty period.

Proof  of  purchase  is  required  to  be  presented  with  any  warranty  claim 

submission.

This  warranty  does  not  apply  to  any  misuse  of  the  pool  pump,  negligence  or 

incorrect  installation. We  will  not  cover  any  damage  due  to  the  pool  pump 

running dry, incorrect chemical balance of pool water, flood damage, damage 

caused by running the pump off an extension cord, damage caused by foreign 

material blocking the impeller (pebbles, organic matter, toys, etc.) or if the pool 

pump is used for any other purpose other than a swimming pool.

We will not be liable for any incidental or consequential damages, loss of time, 

inconvenience,  incidental  expenses,  labour  or  material  charges  in  connection 

with the removal or replacement of the equipment, or costs of transporting the 

goods.

We will not be liable for compensation or damages to any person for any loss, 

injury or damage to any person or property whatsoever, occasioned by or as a 

result of the use of this equipment.

Please Note: Labour and service calls are not included in this warranty.

Any Theraflo pool pump found in a commercial application will only carry a 12 

month warranty from date of purchase.

Register your p

r

oduct w

arr

anty online at 

www.theralux.com.au

or send a copy of p

r

oof of pu

r

chase to 

PO BOX 395 Padstow 2211

THERAFLO CARE & MAINTENANCE

It is strongly advised that you check the hair and lint pot basket area regularly for 

any debris. If debris is found within the basket, you should empty the basket, as 

a  full  basket  can  result  in  reduced  water  flow  and  an  increased  chance  of 

blocking the impeller.

To do this, please ensure that the power to the pump is turned off before you 

remove the lid. You may also need to re-prime the pool pump once the clean 

basket has been returned. Please follow priming instructions found on start-up 

page 10.

Regularly check the pump for any wet areas or leaks. If you find wet areas around 

the pump, please check and re-tension the 2 connecting unions on the inlet & 

outlet PVC lines.

If by chance you find water accumulating at the base of the motor, this could be 

a  sign  of  seal  damage  and  action  should  be  taken  immediately to  avoid  any 

further damage. It is best to consult your local swimming pool professional if this 

arises.

Please do not run your Theraflo TVS pool pump off an extension lead as this 

results in a drop in voltage current which can damage the motor.

Always ensure that the pump itself is free of flooding.

Always ensure that the pump itself is well ventilated. The pump motor will run 

hot  during  its  normal  operation  and  utilises  the  rear  mounted  fan  to  aid  in 

cooling. It is essential that the rear of the pump is clear of all debris and fixtures 

within 100mm.

Do not under any circumstances run your Theraflo TVS swimming pool pump 

without water as this will damage the internal components. Running the pump 

dry will void any warranty so it is imperative that you maintain adequate water 

levels within your swimming pool at all times. Please also be aware when using 

any small pool toys in the swimming pool that may be small enough to block the 

suction line.

Summary of Contents for Theraflo S Series

Page 1: ...t dependable corrosion free service The advanced design reduces operation and maintenance to simple common sense procedures IMPORTANT This appliance is not intended for use by young children unless th...

Page 2: ...residual operating current of 30mA All electrical wiring must be performed by qualified electrical contractor and must conform to electrical regulations and AS3000 wiring rules STARTING AND PRIMING I...

Page 3: ...1 using a 1 2 AF spanner or socket 2 Slide the motor assembly out of the pump strainer housing item 1 exposing the diffuser item 6 Pull the diffuser off the seal plate item 10 exposing the impeller Th...

Page 4: ...impeller ring item 7 back onto the impeller item 8 with its flange facing towards the diffuser item 6 6 Place the diffuser item 6 over the impeller item 8 and onto the seal plate item 10 aligning the...

Page 5: ...raflo 75hp THERAF4308B Impeller suit Theraflo 1hp THERAF4308D Impeller suit Theraflo 1 5hp THERAF4308 E Impeller suit Theraflo 2hp 9 THERAF4309 Seal Assembly 10 THERAF4310 Seal Plate 11 THERAF4311 Mot...

Page 6: ...al balance of pool water ood damage damage caused by running the pump o an extension cord damage caused by foreign material blocking the impeller pebbles organic matter toys etc or if the pool pump is...

Page 7: ...all suction openings E LOW FLOW Generally check for 1 Clogged or restricted strainer or suction line 2 Plugged or restricted discharge line of filter high discharge gauge reading 3 Air leak in suction...