Safety Instructions and Warnings

2

Please read all safety instructions prior to installing your ceiling fan 
and save this document for future reference. If you are in doubt with 
any of the information provided, we recommend that you consult  
or hire a qualified electrician to install your outlet box and ceiling fan.

If you have any questions or difficulty installing your fan,  
call Modern Fan Co customer service at (888) 588-3267.

Note:

 This fan is rated and marked as “Suitable for use in Damp Locations.”  

This fan is suitable for installation in locations protected from weather and subject 
to moderate degrees of moisture, such as some basements, barns, cold storage 
warehouses, and similar locations, and also partially protected locations such as under 
canopies, marquees, roofed open porches, and similar locations. This is not rated,  
nor intended for use in applications classified as Wet Locations.

WARNING

Circuit Breaker

POWER OFF

Warning – To reduce the risk of fire, electrical shock, or personal 
injury please observe the following:

 Mount fan to outlet box marked “Acceptable for Fan Support” and use  

mounting screws provided with the outlet box. Note: Most outlet boxes 
commonly used for light fixtures are not acceptable for fan support and may 
need to be replaced. Consult a qualified electrician if in doubt.

 Prior to installation or servicing always disconnect the power by turning off the 

circuit breakers to the outlet box and associated wall switch location. If you 
cannot lock the circuit breaker in the off position, securely fasten a prominent 
warning device, such as a tag, to the service panel.

 Do not bend the blade brackets when installing the blades, balancing the 

blades, or cleaning the fan. Do not insert foreign objects in between  
rotating fan blades.

 Disconnect the electrical supply circuit to the fan before installing light kit.

 Do not use this fan with any solid-state speed control device other than one 

provided or approved by the manufacturer.

 This fan must be installed with an isolating wall control/switch.

 All wiring must be in accordance with national and local electrical codes  

ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.

 Use this unit only in the manner intended by the manufacturer. If you have  

any questions contact the Modern Fan Co at (888) 588-3267.

 Use only Modern Fan Co replacement parts. 

Summary of Contents for Arbor Flush DC

Page 1: ...DC Installation Instructions and Owners Manual Customer Service Monday Friday 8am 4pm PST tel 888 588 3267 Safety Instructions and Warnings 2 Fan Installation 4 Control Installation and Wiring 7 Trou...

Page 2: ...or Fan Support and use mounting screws provided with the outlet box Note Most outlet boxes commonly used for light fixtures are not acceptable for fan support and may need to be replaced Consult a qua...

Page 3: ...l must be grounded using the attached green wire After making wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the out...

Page 4: ...e screws isolation cover Optional Light Kit parts Hardware Package close up screw pack LED board glass diffuser light plate IMPORTANT The included canopy receiver must be installed and paired with the...

Page 5: ...marked as Acceptable for Fan Support It is recommended that the flat washers and lock washers from the hardware pack be used for added security Electrical supply wires should remain accessible throug...

Page 6: ...ll control into wall box If ordered with a remote control only the power to the ceiling box should be connected through a simple On Off switch leg 3 Wiring Diagram red motor 1 blue for optional light...

Page 7: ...ew holes on fan body align with set screw holes on ceiling plate Take care to not pinch or damage internal wires Insert and firmly tighten three canopy screws from hardware pack Note Do not tighten do...

Page 8: ...dware pack secure blade to motor but do not over tighten Repeat for the two outside screw positions on blade one Follow the same steps for the second and third blade Once all blade screws and washers...

Page 9: ...ght kit lead wires and 2 pin connector through center hole of LED board and carefully insert into 2 pin block Gently push any excess wire behind light plate and position LED board over screw holes on...

Page 10: ...urn power on at the on off wall switch If your fan is installed without a switch leg you will need to use the breaker as your primary power switch for device pairing c Within 1 minute of turning power...

Page 11: ...level Pressing the Fan Off button will stop rotation of the fan but allow continued operation of the light if installed If your fan is equipped with a light pressing and releasing the light button wi...

Page 12: ...installation instructions carefully After reviewing the following troubleshooting tips if you are unable to solve a problem with the installation or operation of you fan please contact customer servic...

Page 13: ...makes repetitive ticking noise Check for obstructions in rotor path Make sure mounting hardware at ceiling is secure Make sure all other hardware and blade attachments are tight Give fan adequate brea...

Page 14: ...eterioration or oxidizing effects of salt or other corrosive elements A Damp Location rating is not an assurance of finish durability Preventative measures should be taken dependent on the environment...

Page 15: ...his warranty only covers the replacement or repair of ceiling fan or parts as specified above and does not cover any other costs incurred related to installation labor or equipment or shipping of fan...

Page 16: ...V2020 08 The Modern Fan Company Inc 709 Washington Street Ashland Oregon 97520 tel 888 588 3267 fax 541 482 8418 info modernfan com modernfan com...

Reviews: