background image

 TH COMMUNICATION SDN BHD    

www.thcomm.com.my

          [email protected] 

Room 

Selecting the virtual room to which the device is 
assigned 

High temperature alarm 

If active, detector will react if temperature is  60°C 
and higher 

Rapid temperature rise alarm 

If active, detector will react on rapid temperature 
rising (30°С for 30 minutes or less) 

Alert with a siren if smoke detected 

If active, HomeSiren and StreetSiren are activated in 
case of smoke alarm 

Alert with a siren if temperature threshold 
exceeded 

If active, HomeSiren and StreetSiren are activated in 
case if temperature threshold exceeded 

Alert with a siren if rapid temperature rise 
detected 

If active, HomeSiren and StreetSiren are activated in 
case if rapid temperature rise detected 

Signal Strength Test 

Switches the device to the signal strength test mode 

FireProtect self-test 

Starts FireProtect self-test 

User Guide 

Opens the detector User Guide 

Unpair Device 

Disconnects the sensor from the hub and deletes its 
settings 

Indication 

Event

 

Indication

 

Detector switch on 

LED lights up green for 1 second 

Detector switch off 

The logo blinks red three times and the device 
switches off 

Registration failed 

The logo blinks greed for a minute, then the 
device switches over to the autonomous mode 

Detector detected smoke contamination and 
temperature increase 

The siren switches on, the logo lights red until 
the end of the fire/smoke detection 

Battery low 

 

One short sound signal per 90 sec - main 
batteries low (CR2) 

 

Two short sound signals per 90 sec - 
backup battery low (CR2032) 

 

Three short sound signals per 90 sec - all 
the batteries low 

Performance testing 

Summary of Contents for FireProtect

Page 1: ...b The communication range is up to 1 300 meters if there are no obstacles In addition the detector can be used as part of third party security central units due to the Ajax uartBridge or Ajax ocBridge Plus integration module Buy fire detector with carbon monoxide sensor FireProtect Plus The detector is set up via a mobile application for iOS and Android based smartphones The user is notified of al...

Page 2: ...connected to a security system the detector will also send an alarm signal to the hub the user and private security company will receive the respective notifications The detector detects smoke using an optical coupler consisting of an infrared emitter and photoelectric receiver located in a smoke chamber If smoke penetrates into the chamber the photoelectric receiver detects it based on the distor...

Page 3: ...tector to the Ajax Security System Connecting to the hub Before starting connection Following the hub instruction recommendations install the Ajax application on your smartphone Create an account add the hub to the application and create at least one room Go to the Ajax application Switch on the hub and check the internet connection via Ethernet cable and or GSM network Ensure that the hub is disa...

Page 4: ...ATION SDN BHD www thcomm com my info thcomm com my 3 Select Add the countdown will begin 4 Switch on the device To make sure that the detector is on press the on off button the logo will light up red for a second ...

Page 5: ...cted to the hub will appear in the list of devices of the hub in the application Update of the detector statuses in the list depends on the device inquiry time set in the hub settings with the default value 36 seconds Connecting the Detector to Third Party Security Systems To connect the detector to a third party security central unit using the Ajax uartBridge or Ajax ocBridge Plus integration mod...

Page 6: ...erature Rapid temperature rise The alarm state for rapid temperature rising Temperature Temperature of the device Measured on the processor and changes gradually Signal Strength Signal strength between the hub and the detector Battery Charge Battery level of the device Backup Battery Charge Backup battery level of the device Lid The tamper mode of the device which reacts to the detachment ...

Page 7: ...us between the hub and the device Smoke detector State of the smoke detector Smoke detector dust level Dust level of smoke chamber Firmware Detector firmware version Device ID Device identifier Setting Up the Detector Devices FireProtect Setting Value First field Device name can be edited ...

Page 8: ...f rapid temperature rise detected Signal Strength Test Switches the device to the signal strength test mode FireProtect self test Starts FireProtect self test User Guide Opens the detector User Guide Unpair Device Disconnects the sensor from the hub and deletes its settings Indication Event Indication Detector switch on LED lights up green for 1 second Detector switch off The logo blinks red three...

Page 9: ... the device Selection of the Detector Location The performance efficiency of the detector depends on its location Location of FireProtect as a security system element determines its remoteness from the hub and presence of any obstacles between the devices hindering the radio signal and sound transmission walls inserted floors large size objects located within the room Check the signal level at the...

Page 10: ...of opening the SmartBracket panel removing the detector from the ceiling you will receive the notification Do not install the detector outside the premises outdoors in places with fast air circulation near a ceiling fan air conditioner air exhaust open doors and windows nearer than a meter from the vertical projection of the cooking surface nearby any metal objects or mirrors causing attenuation a...

Page 11: ...pensated up to some level and then cleaning will be required the detector will send the respective notification The detector also signals about the contaminated smoke chamber or a failure using a long sound signal once every minute and a half How to clean up the smoke chamber Batteries installed in the detector ensure up to 4 years of autonomous operation If the batteries are discharged the securi...

Page 12: ...dimensions 132 х 132 x 31 mm Weight 216 g Complete Set 1 FireProtect FireProtect Plus 2 Batteries CR2 pre installed 2 pcs 3 Battery CR2032 pre installed 1 pcs 4 Installation kit 5 Quick Start Guide Warranty Warranty for the AJAX SYSTEMS MANUFACTURING LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase and does not apply to the pre installed battery If the device does not wor...