For the detection and interfacing to occur, the detector should be located within the coverage
area of the wireless network of the hub (at a single protected object). Request for connection to
the hub is transmitted for a short time at the time of switching on the device.
If the connection to the Ajax hub failed, sensor will work autonomously; switch off the detector
for 5 seconds and repeat the attempt.
The detector connected to the hub will appear in the list of devices of the hub in the application.
Update of the detector statuses in the list depends on the device inquiry time set in the hub
settings, with the default value - 36 seconds.
Connecting the Detector to Third Party Security Systems
To connect the detector to a third party security central unit using the Ajax uartBridge or Ajax
ocBridge Plus integration module, follow the recommendations in the manual of the respective
device.
The smoke detector always operates in the active mode. When connecting FireProtect to third-
party security systems, it is appropriate to place it in a permanently active protection zone.