background image

17

16

LUMAX

– Wireless weather station 

Power consumption:

Batteries 2 x 1.5 V AA (included)

Transmission range: 

Max. 30 m

Transmission frequency: 

433 MHz

Maximum radio-frequency power:

< 10mW

Housing dimensions:

75 x 27 x 93 mm

Weight:

87 g (instrument only)

No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are
correct at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply enter-
ing the product number in the search box.

EU declaration of conformity

Hereby, TFA Dostmann declares that the radio equipment type 35.1093 is in compliance with Directive
2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet address: 
www.tfa-dostmann.de/service/downloads/ce

www.tfa-dostmann.de

E-Mail: [email protected]

TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
Commercial registration number: Reg. Gericht Mannheim HRA 570186

01/21

LUMAX

– Wireless weather station 

No DCF reception

See: No transmitter reception 

Manual time setting

Wait for attempted reception during the night

Incorrect indication

Press RESET button

Change the batteries

If your device fails to work despite these measures, contact the retailer where you purchased
the product. 

14. Waste disposal

This product has been manufactured using high-grade materials and components which can
be recycled and reused. 

Never dispose of empty batteries and rechargeable batteries in household waste. 
As a consumer, you are legally required to take them to your retail store or to an
appropriate collection site depending on national or local regulations in order to
protect the environment.

The symbols for the heavy metals contained are: 
Cd=cadmium, Hg = mercury; Pb=lead 

This product is labelled in accordance with the EU Waste Electrical and Electron-
ic Equipment Directive (WEEE).

Please do not dispose of this product in ordinary household waste. As a con-
sumer, you are required to take end-of-life devices to a designated collection
point for the disposal of electrical and electronic equipment, in order to ensure
environmentally-compatible disposal. 

15. Specifications

Base station

Measuring range indoor temperature:

-10…+60°C 

Resolution:

0,1°C

Operating temperature:

0…+50°C

Power consumption:

Power supply (included)
Input: 100-240V AC 50/80Hz 0.3A
Output: 5.0 V DC 1.0A, 5.0W
Average active efficiency: 

73.62%

No-load power consumption: 

0.10 W

Backup batteries 2 x 1.5 V AAA (included)

Housing dimensions:

80 x 25 x 180 mm

Weight:

243 g (instrument only)

Outdoor transmitter

Measuring range outdoor temperature:

-20…+60°C 

Resolution:

0.1°C

TFA_No_35.1093_Anleitung_01_21  27.01.2021  10:36 Uhr  Seite 9

Summary of Contents for 35.1093

Page 1: ...Instruction manual Mode d emploi Istruzioni per l uso Gebruiksaanwijzing Instrucciones de uso Instruction manuals www tfa dostmann de en service downloads instruction manuals TFA_No_35 1093_Anleitung_...

Page 2: ...garna i din manual kommer att f rhindra skador p ditt instrument och f rlust av dina lagstadgade r ttigheter som uppst r p grund av felak tig anv ndning V nligen ta s rskild h nsyn till s kerhetsr den...

Page 3: ...Inbetriebnahme und den Umgang mit dem Ger t und erhalten Tipps f r den St rungsfall Durch die Beachtung der Bedienungsanleitung vermeiden Sie auch Besch digungen des Ger tes und die Gef hrdung Ihrer...

Page 4: ...O Sensorkabel mit Stromanschlussbuchse P St nder optional Q Batteriefach 5 2 Sender Fig 2 D1 bertragungsanzeige LED D2 Wandaufh nge se D3 Batteriefach Halter D4 Channel Taste 6 Inbetriebnahme Legen S...

Page 5: ...t ndige N sse belastet die elektronischen Bauteile unn tig Pr fen Sie ob eine bertragung der Messwerte vom Au ensender am gew nschten Auf stellort zur Basisstation stattfindet Reichweite Freifeld max...

Page 6: ...device immediately if any fault occurs The base station and the mains adapter must not come into contact with water or mois ture Only suitable for operation in dry interiors Do not use the unit if th...

Page 7: ...time is coded and transmitted from Mainflingen near Frank furt via frequency signal DCF 77 77 5 kHz and has a transmitting range of approximately 1 500 km Your radio controlled clock receives this si...

Page 8: ...ce of interference LUMAX Wireless weather station 7 Operation The instrument will automatically quit the setting mode if no button is pressed within 10 seconds 7 1 Manual setting of the clock Press an...

Page 9: ...ork despite these measures contact the retailer where you purchased the product 14 Waste disposal This product has been manufactured using high grade materials and components which can be recycled and...

Page 10: ...ez toutes les fonc tions et tous les l ments qui le composent vous noterez les d tails importants relatifs sa mise en service et vous lirez quelques conseils en cas de dysfonctionnement En respectant...

Page 11: ...2 D1 Affichage transfert DEL D2 Support pour suspension murale D3 Appuis pour compartiment piles D4 Touche CH 6 Mise en service D poser la station de base et l metteur ext rieur sur une table une dist...

Page 12: ...e entre l metteur l emplacement d sir et la station de base port e avec champ libre environ 30 m tres sont bien transmises en cas de murs massifs en particulier comportant des parties m talliques la p...

Page 13: ...aete immediatamente la spina dalla presa di corrente qualora rileviate un guasto La stazione base e l alimentatore non devono venire a contatto con acqua o umidit Il dispositivo adatto esclusivamente...

Page 14: ...in un milione di anni L ora codificata e viene trasmessa da Mainflingen vicino a Francoforte con un segnale a frequenza DCF 77 77 5 Khz ed ha un raggio di trasmissione di circa 1 500 km L orologio rad...

Page 15: ...larit Richiudete i coperchi Attenzione Dopo aver sostituito le batterie necessario ristabilire il contatto tra il trasmettitore e il ricevitore pertanto cambiate sempre le batterie contemporaneamente...

Page 16: ...imentatore Nessuna ricezione del trasmettitore Non stato installato il trasmettitore Indicazione Controllate le batterie del trasmettitore per il canale 1 2 3 esterno non utilizzate batterie ricaricab...

Page 17: ...llen van het apparaat en de omgang ermee en krijgt u tips voor het geval van een storing Door rekening te houden met wat er in de handleiding staat vermijdt u ook beschadi gingen van het product en ri...

Page 18: ...Buitenzender Fig 2 D1 LED signaallamp D2 Wandophanging D3 Batterijvak houders D4 CH toets 6 Inbedrijfstelling Leg de buitenzender en het basisapparaat op een afstand van ca 1 5 meter van elkaar op ee...

Page 19: ...rdracht van de meetwaarden van de zender op de gewenste opstel lingsplaats naar het basisapparaat plaatsvindt reikwijdte vrij veld ca 30 meter Massieve wanden in het bijzonder met metalen delen kunnen...

Page 20: ...amente de la toma de corriente si se produce perturbaci n El dispositivo base y la fuente de alimentaci n no deben entrar en contacto con agua ni con humedad Solo son aptos para el funcionamiento en i...

Page 21: ...desde Mainflingen en las pro ximidades de Frankfurt am Main por una se al de frecuencia DCF 77 77 5 kHz con un alcan ce de aprox 1 500 km Su reloj radiocontrolado recibe la se al la convierte y muest...

Page 22: ...ador de red LUMAX Estaci n meteorol gica inal mbrica Por las noches las perturbaciones atmosf ricas suelen ser reducidas y disponer de recep ci n en la mayor a de los casos Si adem s se recibe como m...

Page 23: ...stica El usuario est obliga do a llevar el dispositivo usado a un punto de recogida de aparatos el ctricos y electr nicos acreditado para que sea eliminado de manera respetuosa con el medio ambiente 1...

Page 24: ...P 47 46 Fig 1 B 1 3 5 7 D E H K J O C N 2 4 6 8 Q F G I L M A Fig 2 D3 D3 D2 D4 D1 TFA_No_35 1093_Anleitung_01_21 27 01 2021 10 36 Uhr Seite 24...

Reviews: