HK12ID Dieless Crimping Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Operation
(cont’d)
Crimping
(cont’d)
4. For a UL or cUL classified crimp, complete the
number of crimps specified in the Connector Table
below.
5. For a single crimp, position the connector so the
crimp will be located at the center of the barrel.
For a double crimp, position the connector so two
crimps will be evenly spaced between the connec-
tor marks.
6. Pump the handle to advance the indenter. Continue
to pump the handle until the pressure relief valve
activates.
Note: Pressure relief is indicated by an audible
“pop”. The handle load will also drop suddenly to
indicate a complete crimp.
7. Retract the indenter by twisting the pump handle
clockwise in the open position and closing the
handle to activate the release valve. Continue to
hold the pump handle closed to completely retract
the indenter.
8. Lift the latch to open the crimping head and remove
the connector.
9. After completing the last crimp on an aluminum
connector, wipe off the excess oxide inhibitor.
Note: if it is necessary to retract the indenter before a
crimp cycle is complete, raise the pump handle, twist
clockwise, and close the handle to activate the release
valve and retract the indenter.
cUL and UL Classified Crimps
Crimps made with the Greenlee HK12ID Dieless Crimping Tool are cUL and UL classified on standard
concentric, compressed, or compact stranded copper and aluminum cable with the connectors listed
here. Refer to the Connector Table for the brand names and model numbers of appropriate connectors
and the number of crimps required.
Connector Table
Copper Connector Type
Anderson Blackburn
®
Burndy
ILSCO
Panduit
T & B
Penn-
Union
Tyco (AMP)
Copper Splices
VHSS
VHS
CSP
CU
YS-L
YS
CT
CTL
SCSS
SCS
SCL, SCH
54506 to 54528
54806 to 54828
BCU
BBCU
—
Copper Lugs
VHCS
VHCL
CTL
CTL-L
LCN
YA, YA-L, YA-2L
YA-2LN, YA-2N
YA-L-TC, YA-L-2TC
YA-2TC, YAZ
YAZ-2N, YAZ-2TC
CLN, CLW, CSW
CRA, CRB, CRC
CRA-L, CRB-L
CRA-2L
CRB-2L
CRC-2L
LCAS
LCA
LCB
LCD, LCC
LCAN
54106 to 54128
54206 to 54228
54906BE to 54928BE
54854BE to 54882BE
BLU
BBLU
1099898-2 to
1-1099898-5,
1099899-2 to
1-1099899-9,
1099939-1 to
1-1099939-5
Number of
Crimps*
Copper Cable Size:
4 AWG to 1000 kcmil
1
1
1
1
1
1
1
1
Aluminum Connector Type
Anderson Blackburn
®
Burndy
ILSCO
Panduit
T & B
Penn-
Union
Dual-Rated Aluminum Splices
VACS
ASP
YS-A
AS, ASN
SA
60507 to 60584
PIK
BCUA
Dual-Rated Aluminum Lugs
VACL
ATL
YA-A
YA-A-TN
ACL, ACN
2ACL, 2ACN
ALNS, ALNN
ALND
LAA
LAB
60106 to 60184
60230 to 60284
BLUA
Number of
Crimps*
Cable Size: 6 AWG to 500 kcmil
1
1
1
1
1
1
1
Cable Size: 600 kcmil to 800 kcmil
2
1
1
1
2
1
1
Cable Size: 1000 kcmil
2
2
2
2
2
2
2
* When crimping with the HK12ID crimping tool, use the number of crimps listed in this table