EK622PLT and EK622PLX Battery-powered Crimping Tools
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
Die Selection
Crimps made on copper cable with Greenlee KC22-type dies and the copper connectors listed here are
cUL and UL classified.
Crimps made on copper or aluminum cable with Greenlee KA22-type dies and the dual-rated aluminum connectors
listed here are cUL and UL classified.
Refer to “Connector Selection” for brand names and model numbers of appropriate lugs as well as crimping
instructions.
W-type or X-type dies can be used to crimp 8 AWG to 500 kcmil copper and 8 AWG to 4/0 AWG aluminum.
Dies for Dual-rated Aluminum Connectors
Catalog Number
UPC Number
Cable Size
KA22-8
06744
8 AWG
KA22-6
06745
6 AWG
KA22-4
06746
4 AWG
KA22-2
06747
2 AWG
KA22-1
06749
1 AWG
KA22-1/0
06750
1/0 AWG
KA22-2/0
06751
2/0 AWG
KA22-3/0
06752
3/0 AWG
KA22-4/0
06753
4/0 AWG
KA22-250
06754
250 kcmil
KA22-300
06755
300 kcmil
KA22-350
06756
350 kcmil
Dies for Copper Connectors
Catalog Number
UPC Number
Cable Size
Color Code
KC22-8
03079
8 AWG
Red
KC22-6
03080
6 AWG
Blue
KC22-4
03081
4 AWG
Gray
KC22-2
03082
2 AWG
Brown
KC22-1
03083
1 AWG
Green
KC22-1/0
03084
1/0 AWG
Pink
KC22-2/0
03085
2/0 AWG
Black
KC22-3/0
03086
3/0 AWG
Orange
KC22-4/0
03087
4/0 AWG
Purple
KC22-250
03088
250 kcmil
Yellow
KC22-300
03089
300 kcmil
White
KC22-350
03090
350 kcmil
Red
KC22-400
03091
400 kcmil
Blue
KC22-500
03092
500 kcmil
Brown
KC22-600
03093
600 kcmil
Green
Connector Selection
Tool Range:
Copper — 8 AWG to 600 kcmil; Dual-rated Aluminum — 8 AWG to 350 kcmil
When used with KC22-type dies, this tool is cUL and UL classified for use with the following connector brands:
Connector
Type
Barrel
Type
Anderson Blackburn
®
Burndy
ILSCO
Panduit
T&B
Penn-
Union
No. of
Crimps*
Copper
Splice
Short
VHSS
CSP
YS-L
CT
SCSS/SCS
54504-54520
BCU
A
Long
VHS
CU
YS
CTL
SCL/SCH
54804-54820
BBCU
B
Copper
Lugs
Short
VHCS
CTL-2/CTL
YA-2LN/YA-L/YA-2L
YA/YA-L-TC/YA-L-2TC
CSW
CRA/CRB
LCAS/LCA
LCD
54104-54120
54204-54218
BLU
A
Long
VHCL
CTL-L/LCN
YA-2N
CLN/CLW
CRA-L/CRB-L
CRA-2L/CRB-2L
LCB/LCC
54930BE-54920BE
54850BE-54878BE
BBLU
B
When used with KA22-type dies, this tool is cUL and UL classified for use with the following connector brands:
Connector Type
Barrel Type Anderson
Blackburn
®
Burndy
ILSCO
Panduit
T&B
Penn-
Union
No. of
Crimps*
Dual-rated
Aluminum Splice
—
VACS
ASP
YS-A
AS
ASN
SA**
60501-60565
PIK
C
Dual-rated
Aluminum Lugs
—
VACL
ATL
YA-A
YA-ATN
ACL/ACN
2ACL/2ACN
ALNS/ALNN/ALND
LAA/LAB**
60101-60166
60230-60267
BLUA
C — 8 to 2 AWG: 2 crimps
1 to 3/0 AWG: 3 crimps
4/0 AWG to 350 kcmil: 4 crimps
B — 8 to 1/0 AWG: 2 crimps
2/0 to 3/0 AWG: 3 crimps
4/0 AWG to 600 kcmil: 4 crimps
A — 8 to 1/0 AWG: 1 crimp
2/0 AWG to 600 kcmil: 2 crimps
** 6 AWG to 350 kcmil
* Use the number of crimps listed in the last column instead of the number provided with the connector:
95R7