5-22.
EACH 150 HOURS OF STARTER GENERATOR (200SG119Q) OPERATION
DATA REFERENCE
INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: _________________
_________________________
HELICOPTER S/N: __________
_________________________
REGISTRY NO.: ____________
_________________________
TOTAL TIME:_______________________________________
SIGNATURE: _______________
_________________________
NOTE
Accomplish each 150 hours of starter generator
200SG119Q operation or more frequently if
conditions warrant.
Part number 200SG119Q refers to the starter
generator without the QAD kit consisting of the
mounting flange and ring clamp.
This special inspection is not applicable to starter
generator 209-060-221-001.
Chapter 71
1.
Remove starter generator 200SG119Q.
2.
Inspect starter generator brushes for wear.
TM106 – Aircraft
Parts Corp. Overhaul
Instructions with
Illustrated Parts
Breakdown
3.
If brushes are worn beyond allowable limits, refer to
vendor manual and replace in accordance with manufacturer’s
instructions.
4.
Install starter generator.
26 FEB 2013
Rev. 16
Page 131/132
Summary of Contents for Bell 412
Page 6: ......
Page 12: ......
Page 32: ......
Page 40: ......
Page 152: ......
Page 154: ......
Page 156: ......
Page 158: ......
Page 160: ......
Page 164: ......
Page 166: ......
Page 168: ......
Page 172: ......
Page 174: ......
Page 198: ......
Page 202: ......
Page 220: ......
Page 224: ......
Page 232: ......
Page 234: ......
Page 236: ......
Page 242: ......
Page 256: ......
Page 262: ......
Page 268: ......
Page 288: ......