100
7-2-2. Probe Specifications
Model
GTP-100B-4
Position X10
Attenuation Ratio
10:1
Bandwidth
DC
~
100MHz
Input Resistance
10MΩ when used with oscilloscopes
with 1MΩ input.
Input Capacitance
14.5pF~17.5pF
Compensation Range
5
~
30pF
Max. Input Voltage
≤600V DC + ACpk
(When the input frequency is high,
the maximum voltage will decrease.)
Position X1
Attenuation Ratio
1:1
Bandwidth
DC
~
10MHz
Input Resistance
1MΩ when used with oscilloscopes
with 1MΩ input.
Input Capacitance
85pF~115pF
Max. Input Voltage
≤200V DC + ACpk
(When the input frequency is high,
the maximum voltage will decrease.)
Operating Cond.
Temperature
–10°C ~ 45°C
Relative Humidity
≤85%
anytime without notice for probe model types of similar specification.
Summary of Contents for DCS-4605
Page 1: ...INSTRUCTION MANUAL DIGITAL STORAGE OSCILLOSCOPE DCS 4605 B71 0392 01 ...
Page 12: ......
Page 81: ...69 ...