Premier Elite Series Installation Manual
Global Options
INS176-15
77
Holiday Dates
E o elec:
loal pions
loal pions
yse ies
Holiday ae 3
//
Ene ne dae
3//
Holiday ae 3
//
loal pions
Holiday aes
Holiday ae
//
y
7
y
y
y
The system has 24 programmable holiday dates.
The holiday dates are pre-defined dates on which the Control Timers
will not operate.
Example
Control Timer 1 is programmed to operate between the hours of 8pm
and 8am on Monday through to Friday (for the purpose of arming the
control panel).
Because Bank Holidays normally fall on Mondays the panel would
disarm itself leaving the premises unprotected.
•
Christmas day 2001 falls on a Tuesday
•
Under normal conditions the Control Timer will operate on a
Tuesday
•
The 25/12/01 is programmed as a Holiday Date
•
The Control Timer does not operate on Tuesday 25
th
December
2001 and the premises remains protected at all times
Speaker Tones
E o elec:
loal pions
loal pions
yse ies
loal pions
peae ones
peae ones
E
Eny ones
E
ie ones
E
Eny ones
y
8
y
n
n
y
The speaker output on the control panel can be programmed so that
certain types of tones are not generated. When deselected, Fire,
Alarms, Fault, Service, Entry, Exit and Chime tones will not be heard.
Select tones by pressing keys 1 to 8 (a letter on the display means
the tone is selected, a Dot on the display means the tone is not
selected).
F - Fire Tones On
Fire alarm tones will be generated by the control panel
sounder/speaker.
A - Alarm Tones On
Intruder alarm, Tamper alarm and PA alarm tones will be generated
by the control panel sounder/speaker.
F - Fault Tones On
Fault tones will be generated by the control panel sounder/speaker.
S - Service Tone On
Service and Warning tones will be generated by the control panel
sounder/speaker.
E - Entry Tones On
Entry tones will be generated by the control panel sounder/speaker.
X - Exit Tones On
Exit tones will be generated by the control panel sounder/speaker.
C - Chime Tones On
Chime 1, 2 and 3 tones will be generated by the control panel
sounder/speaker.