Global Options
Premier Elite Series Installation Manual
70
INS176-15
27 - Warning Delay
When a Custom zone with the ‘Warning Req’ attribute (see page
for details) activates, this timer is started. If the zone is still active
when this timer expires a warning tone or alarm will occur and the
Warning Output (see page 87 for details) will activate.
28 - Keypad Lock Time
When code tampers are programmed to lockout the keypad (see
page 71 for details), the keypad will lock out for the duration of this
timer.
29 - Eng. log off Dly
This timer starts when an Engineers code is entered. When the timer
expires the engineer is automatically logged out of engineer’s mode. Th
is
timer is suspended if there are tamper faults on the system allowing the
engineer to remain in engineer’s mode indefinitely whilst on site.
30 - Fire Bell Delay
This timer starts when a fire alarm is generated in a particular area.
When the timer expires sounders are activated in ALL areas.
31 - Forced Entry Dly
When a zone with the ‘Guard’ attribute (see page
58 for details)
activates, this timer is started. For the duration of this timer, any
‘Entry/Exit 1 or 2’ zone with the ‘Entry/Exit 2’ attribute (see page
for deta
ils) will become a ‘Guard’ zone. When this timer expires, the
‘Entry/Exit 1 or 2’ zone will revert back to its normal mode of
operation.
32 - Supervision Time
This timer controls the frequency at which the Ricochet devices are
required to report in to the control panel.
33 - Poll IP Every
This timer controls the frequency that the ComIP Polls the ARC.
34 - Confirmed PA Timer
When an PA alarm occurs, this timer starts. If a second (different) PA
zone is activated
within this time window, the ‘Confirmed PA’ o
utput
will activate. When this timer expires, the ‘Confirmed PA’ output will
no longer activate.
35 - Seismic Timer 1*
36 - Seismic Timer 2*
37 - Seismic Timer 3*
*
Reserved for future use
System Config.
E o elec:
loal pions
loal pions
yse ies
loal pions
yse onig
onigaion
o ell e ail
onigaion
is Unloced
onigaion
is oced
y
1
y
n
y
These options control how various system functions work.
00 - No Bell Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Strobe’
output will activate.
Bell on Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Bell’
output will activate for 10 seconds.
The ‘Strobe’ output will also activate for 5 seconds to indicate
that the system has armed/disarmed.
01 - Bell is an SAB
The ‘Bell’ output on the control panel applies 0V when active.
Bell is an SCB
The ‘Bell' output on the contro
l panel removes 0V when active.
02 - Clock is 24Hr
The system time is displayed in the 24-Hour format.
Clock is 12Hr (Default)
The system time is displayed in the 12-Hour format.
03 - Auto BST/GMT
The system clock will adjust itself at the beginning and the end of the
summer (the clock will automatically gain 1Hr on the last Sunday in
March and lose 1Hr on the last Sunday in October.
Manual BST/GMT
The system clock will not adjust itself at the beginning and the end of
the summer (the clock will have to be adjusted manually).
04 - View Armed Areas
When the system is part armed, the areas that are armed are
displayed and alarm information is displayed before a valid User
code is entered.
Hide Armed Areas
When the system is part armed, the areas that are armed are not
displayed and alarm information is only displayed after a valid User
code has been entered.