Odyssey X
Installation Manual
INS627-2
7
Learning the Sounder (
Odyssey X-W
only)
As with all
Ricochet
enabled devices, the sounder should be learned to the control panel along with all other devices BEFORE it is installed in its
final location.
The
Odyssey X-W
are learned to a Zone on the control panel in the same way that
Ricochet
enabled detection devices are. The Zone type and
Ricochet
Device Mode is automatically assigned based on the type of device being learned. In the case of the sounder the Zone Type is set to
"Custom" and the
Ricochet
Device Mode is set to Device Specific. These should not be changed. Zone attributes 1 & 2 and Chime options will be
ignored for
Ricochet
enabled Sounders.
•
You can learn the device from first power up following
"Confirm Devices"
or from the dedicated
Ricochet
Learn menu.
•
The
Odyssey X-W
has no Learn Switch, learning is initiated by connecting the batteries via the Power Jumper
•
To learn the Odyssey X-W to the system follow the diagram below.
/
N?, E?, D??
- 20s
The bottom line of text shows
the one number, the etwork
and the xpander the device will
be learned too.
Z
N
E
The bottom line of text shows
the etwork the xpander and
the device slot on the expander.
N
E
/
/
/
Use the
/
or
to
select different zones. It is only
possible to selec t Zones which
are free.
/
LED Indications (
Odyssey X-W
only)
The
Odyssey X-W
LED,s aid in the installation of the device and act as status indicators. The table below details the status of each LED indicator.
T
he LED jumper has no effect on the status described below.
Leds
Status
Left LED flashing quickly
Device is attempting to communicate with receiver after power up.
Left LED flashing slowly
Device has learnt or re-connected to receiver and is waiting for the tamper to be
closed.
Both LEDs off
Device has failed to learn or failed to communicate after tamper has been closed.
Right LED flashing quickly
Device is attempting to communicate with receiver after tamper has been closed.
Right LED on solid (for 3 seconds)
Device has successfully connected with receiver after tamper closed.
Right LED flashing slowly
Holdoff mode has been requested from the panel but the tamper is closed. Bell will
not self-activate. Cancels after 20 minutes.
LEDs alternating quickly.
Device has successfully connected with receiver after tamper closed and self-
activation on tamper will re-activate in 2 minutes.