background image

 

Odyssey X

 Installation Manual 

INS627-2 

Adjusting removal from mounting tamper 

The removal from mounting tamper screw must be used on all surfaces;  on 

uneven surfaces it will prevent the keyhole screw from damaging the tamper 
breakout. .  

The screw should be driven in until it makes contact with the wall.  

 

Failure to do this may result in incorrect operation of the tamper 
circuit. 

 

 

 

Internal Lid Tamper 

The 

Odyssey X

 is fitted with an internal lid tamper to prevent access to the electronics and wiring of the unit. The screw located on the inside of 

the internal hinged lid should be adjusted so that the tamper switch closes correctly when the lid is screwed into place. 

 

Wiring the Unit 

Connect the unit to the control panel as follows: 

A

 (12V)   

Permanent Positive Supply 

B

 (BELL)   

Negative Applied Output to Activate Siren 

C

 (TAMP)  

Negative Removed on Tamper Input 

D

 (0V) 

 

Permanent Negative Supply 

S

 (STRB)   

Negative Applied Output to Activate Strobe 

T

 (Test) 

Test input for enabling remote test via 
Maintex or Wintex* 

Tamper Relay 

Negative Removed on Tamper Input* 

Fault Relay 

Reports Faults from the sounder* 

 

Not applicable to Odyssey X-E & X-BE

 

Although the unit has been designed to be compatible with a wide range of control panels, for optimum performance, it is 

highly recommended that the unit should be used with Texecom's range of control panels. 

Summary of Contents for Odyssey X

Page 1: ...Odyssey X Series Installation Manual INS627 2...

Page 2: ...cklight Single Piezo Odyssey X W Premier Elite V2 11 or later Grade 2 Wireless Sounder Strobe Unit Single Piezo Odyssey X D Decoy backplate without electronics Covers Options Outer Colour Infill Lens...

Page 3: ...o remove it completely and depress the tab to open the lid The Lid has two parked positions Undo the screw and press the tab to access Wiring Tamper Inner cover open Removing the lid completely To com...

Page 4: ...he light diffuser upwards to release Please make sure this operation is done in a clean dry environment where the diffuser and lid are not likely to be scratched or damaged 2 Insert the Graphic A Plac...

Page 5: ...the light diffuser upwards to release Please make sure this operation is done in a clean dry environment where the diffuser and lid are not likely to be scratched or damaged 2 Insert the Graphic A Pl...

Page 6: ...ck should be connected here after installing the batteries Powering the sounder on for the first time starts the learn process Once learned the POWER jumper should be left in the ON position If you ne...

Page 7: ...will be learned too Z N E The bottom line of text shows the etwork the xpander and the device slot on the expander N E Use the or to select different zones It is only possible to select Zones which a...

Page 8: ...to the dual tamper microswitch In doing so care must be taken to leave the screw head slightly proud to ensure that the microswitch remains level and closes correctly when the inner cover is fitted F...

Page 9: ...lid should be adjusted so that the tamper switch closes correctly when the lid is screwed into place Wiring the Unit Connect the unit to the control panel as follows A 12V Permanent Positive Supply B...

Page 10: ...er circuit closed it will NOT sound for 5 seconds and will NOT enter Hold Off mode In order to disable the S A function before the cover is removed Hold Off mode should be invoked as for servicing see...

Page 11: ...demand on the control panel will enable the connection of additional sounder units To select SCB Mode the unit should first be powered from the built in battery by either using the jumper included on...

Page 12: ...is removed the left LED only will flash to indicate that the tamper circuit is open If remote power is removed and the tamper circuit is left closed the right LED with flash rapidly to indicate that t...

Page 13: ...Models Type NiMh Stack Operating Temperature 25 C 13 F to 55 C 131 F Voltage 7 2VDC nominal Storage Temperature 25 C 13 F to 60 C 140 F Capacity 250mAh EMC Environment Residential Commercial Light In...

Page 14: ...Type B Moveable devices and are suitable for use in systems designed to comply with EN 50131 1 EN50131 4 EN50131 5 3 and PD6662 at Grade 2 3 and Environmental Class IV All E W Models are Grade 2 and a...

Page 15: ...Odyssey X Installation Manual INS627 2 15 Notes...

Page 16: ...hire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1706 2...

Reviews: