background image

Odyssey X 

Installation Manual 

14 

INS627-2 

Standards 

 

Texecom declares that this product complies with the requirements of the following directives 

 

1999/5/EC 

R&TTE Directive (Odyssey X-W) 

 

2004/108/EC 

EMC Directive 

 

2006/95/EC  

LVD Directive 

 

2011/65/EU  

ROHS Directive 

The product therefore meets all the requirements to enable it to be CE marked.  

 

 

Weee Directive

: Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper 

recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection 

points. For more information see: www.recyclethis.info. 

These products are Type B Moveable devices and are suitable for use in systems designed to comply with EN 50131-1, EN50131-4, EN50131-5-3  and PD6662 at 

Grade 2 & 3 and Environmental Class IV. All E & W Models are Grade 2 and all non E Models are Grade 3. 

Warranty 

All Texecom products are designed for reliable, trouble-free operation. Quality is carefully monitored by extensive computerised testing. As a result the

 

Odyssey X

 range is

 

covered by a two year warranty (excludes batteries) against defects in material or workmanship (details on request).   

Because the 

Odyssey X

 are not complete alarm systems but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a 

claim that a unit failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice. 

Odyssey

 

is a trademark of Texecom Ltd. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Odyssey X

Page 1: ...Odyssey X Series Installation Manual INS627 2...

Page 2: ...cklight Single Piezo Odyssey X W Premier Elite V2 11 or later Grade 2 Wireless Sounder Strobe Unit Single Piezo Odyssey X D Decoy backplate without electronics Covers Options Outer Colour Infill Lens...

Page 3: ...o remove it completely and depress the tab to open the lid The Lid has two parked positions Undo the screw and press the tab to access Wiring Tamper Inner cover open Removing the lid completely To com...

Page 4: ...he light diffuser upwards to release Please make sure this operation is done in a clean dry environment where the diffuser and lid are not likely to be scratched or damaged 2 Insert the Graphic A Plac...

Page 5: ...the light diffuser upwards to release Please make sure this operation is done in a clean dry environment where the diffuser and lid are not likely to be scratched or damaged 2 Insert the Graphic A Pl...

Page 6: ...ck should be connected here after installing the batteries Powering the sounder on for the first time starts the learn process Once learned the POWER jumper should be left in the ON position If you ne...

Page 7: ...will be learned too Z N E The bottom line of text shows the etwork the xpander and the device slot on the expander N E Use the or to select different zones It is only possible to select Zones which a...

Page 8: ...to the dual tamper microswitch In doing so care must be taken to leave the screw head slightly proud to ensure that the microswitch remains level and closes correctly when the inner cover is fitted F...

Page 9: ...lid should be adjusted so that the tamper switch closes correctly when the lid is screwed into place Wiring the Unit Connect the unit to the control panel as follows A 12V Permanent Positive Supply B...

Page 10: ...er circuit closed it will NOT sound for 5 seconds and will NOT enter Hold Off mode In order to disable the S A function before the cover is removed Hold Off mode should be invoked as for servicing see...

Page 11: ...demand on the control panel will enable the connection of additional sounder units To select SCB Mode the unit should first be powered from the built in battery by either using the jumper included on...

Page 12: ...is removed the left LED only will flash to indicate that the tamper circuit is open If remote power is removed and the tamper circuit is left closed the right LED with flash rapidly to indicate that t...

Page 13: ...Models Type NiMh Stack Operating Temperature 25 C 13 F to 55 C 131 F Voltage 7 2VDC nominal Storage Temperature 25 C 13 F to 60 C 140 F Capacity 250mAh EMC Environment Residential Commercial Light In...

Page 14: ...Type B Moveable devices and are suitable for use in systems designed to comply with EN 50131 1 EN50131 4 EN50131 5 3 and PD6662 at Grade 2 3 and Environmental Class IV All E W Models are Grade 2 and a...

Page 15: ...Odyssey X Installation Manual INS627 2 15 Notes...

Page 16: ...hire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1706 2...

Reviews: