![Texas Smart G-Force SB1200 User Manual Download Page 84](http://html1.mh-extra.com/html/texas/smart-g-force-sb1200/smart-g-force-sb1200_user-manual_1093828084.webp)
32
Once the boundary cable has been correctly connected in the charging station, it must be
secured using the four pegs. This is to ensure that the charging station does not move and
cause damage to the cable.
The 230 V power supply can now be connected to the charging station.
A small LED will now light up. If the LED is BLUE, everything is OK and there is a
connection to the boundary cable.
If the LED does not come on, first check the 230 V power supply connection is correctly
setup.
If the LED does not switch on and remain blue all of the time, and there is nothing wrong
with the 230 V power supply connection, use the troubleshooting table to remedy the
problem.
LED
DESCRIPTION
1 Lit
Blue
Normal
2 Flashing
Blue
,
Red
switched
off
Internal cable break in the charging station, boundary
cable OK.
Check the cable under the charging station.
3 Flashing
Red
,
Blue
switched
off
Break in the boundary cable, charging station cable
OK.
If required, check the cable connections. Check the
charging station’s cable input.
4 Flashing
Red
and
Blue
Boundary cable and internal charging station cable,
break or short circuit.
If required, check the cable connections. Check the
charging station’s cable input.