RamSan-325/325c
User’s Manual
- 115 -
Name battery-state-notif
Description The battery state has changed
Includes
Message
Battery State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState
N/A
1 error
The battery has failed a periodic battery test and
may need to be serviced, or one or more of the
batteries have voltages that threaten the system’s
ability to backup data in the event of a power loss.
2 warn
The batteries may be charging after being used,
this is expected after power loss. Alternatively, the
battery voltages may be below specification but
not dangerously low.
3 good
The batteries are all operating properly.
4 warnHigh
Battery voltages or currents are above
specification, but not dangerously high.
5 errorHigh
Battery voltages or currents are dangerously high;
the system should be serviced.
6 noDevice
N/A
7 notMonitored
Monitoring has been turned off to suppress
warnings. Normal in systems without batteries.