54
SLOS743L – AUGUST 2011 – REVISED MARCH 2017
Product Folder Links:
Detailed Description
Copyright © 2011–2017, Texas Instruments Incorporated
Table 6-21. Register Values After Sending Software
Initialization (0x03) (continued)
ADDRESS
REGISTER
VALUE
(2)
Default value may not always be 0x00. See the
for
details.
0x0B
Regulator and I/O control
0x87
0x0C
IRQ status
0x00
0x0D
Collision position and interrupt mask
0x3E
0x0E
Collision position
0x00
0x0F
RSSI levels and oscillator status
0x40
0x10
Special function
0x00
0x11
Special function
0x00
0x12
RAM
0x00
0x13
RAM
0x00
0x14
Adjustable FIFO IRQ levels
0x00
0x15
Reserved
0x00
0x16
NFC low field detection level
0x00
0x18
NFC target detection level
0x00
(2)
0x19
NFC target protocol
0x00
0x1A
Test
0x00
0x1B
Test
0x00
0x1C
FIFO status
0x00
6.14.1.3 Initial RF Collision Avoidance (0x04)
See the
.
6.14.1.4 Response RF Collision Avoidance (0x05)
See the
.
6.14.1.5 Response RF Collision Avoidance (0x06, n = 0)
See the
.
6.14.1.6 Reset FIFO (0x0F)
The reset command clears the FIFO contents and FIFO Status register (0x1C). It also clears the register
storing the collision error location (0x0E).
6.14.1.7 Transmission With CRC (0x11)
The transmission command must be sent first, followed by transmission length bytes, and FIFO data. The
reader starts transmitting after the first byte is loaded into the FIFO. The CRC byte is included in the
transmitted sequence.
6.14.1.8 Transmission Without CRC (0x10)
Same as
with CRC excluded.
6.14.1.9 Delayed Transmission With CRC (0x13)
The transmission command must be sent first, followed by the transmission length bytes, and FIFO data.
The reader transmission is triggered by the TX timer.