![Texas Instruments TMS320x2823x Reference Manual Download Page 40](http://html1.mh-extra.com/html/texas-instruments/tms320x2823x/tms320x2823x_reference-manual_1095205040.webp)
Z
Z
Z
CA
CA
CA
Z
T
CB
T
P
T
CA
T
CB
P
CB
CB
P
Do Nothing
Clear Low
Set High
Toggle
P
Zero
Comp
A
Comp
B
Period
TB Counter equals:
Actions
S/W
force
SW
SW
SW
SW
T
ePWM Submodules
www.ti.com
Actions are specified independently for either output (EPWMxA or EPWMxB). Any or all events can be
configured to generate actions on a given output. For example, both CTR = CMPA and CTR = CMPB can
operate on output EPWMxA. All qualifier actions are configured via the control registers found at the end
of this section.
For clarity, the drawings in this document use a set of symbolic actions. These symbols are summarized in
. Each symbol represents an action as a marker in time. Some actions are fixed in time (zero
and period) while the CMPA and CMPB actions are moveable and their time positions are programmed
via the counter-compare A and B registers, respectively. To turn off or disable an action, use the "Do
Nothing option"; it is the default at reset.
Figure 22. Possible Action-Qualifier Actions for EPWMxA and EPWMxB Outputs
40
TMS320x2833x, 2823x Enhanced Pulse Width Modulator (ePWM) Module
SPRUG04A – October 2008 – Revised July 2009
© 2008–2009, Texas Instruments Incorporated