Functional Unit Constraints
4-49
Pipeline
SPRU733
Table 4
−
33 shows the instruction constraints for 4-cycle instructions executing
on the .L unit.
Table 4
−
33. 4-Cycle .L-Unit Instruction Constraints
Instruction Execution
Cycle
1
2
3
4
5
4-cycle
R
W
Instruction Type
Subsequent Same-Unit Instruction Executable
Single-cycle
Xw
4-cycle
INTDP
ADDDP/SUBDP
Instruction Type
Same Side, Different Unit, Both Using Cross Path Executable
Single-cycle
DP compare
2-cycle DP
4-cycle
Load
Store
Branch
16
×
16 multiply
MPYI
MPYID
MPYDP
Legend:
= E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the
instruction;
= Next instruction can enter E1 during cycle; Xw = Next instruction cannot enter E1 during cycle-write