Functional Unit Constraints
4-41
Pipeline
SPRU733
Table 4
−
25 shows the instruction constraints for 4-cycle instructions executing
on the .M unit.
Table 4
−
25. 4-Cycle .M-Unit Instruction Constraints
Instruction Execution
Cycle
1
2
3
4
5
4-cycle
R
W
Instruction Type
Subsequent Same-Unit Instruction Executable
16
×
16 multiply
Xw
4-cycle
MPYI
MPYID
MPYDP
Instruction Type
Same Side, Different Unit, Both Using Cross Path Executable
Single-cycle
Load
Store
DP compare
2-cycle DP
Branch
4-cycle
INTDP
ADDDP/SUBDP
Legend:
= E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the
instruction;
= Next instruction can enter E1 during cycle; Xw = Next instruction cannot enter E1 during cycle-write