![Texas Instruments SWRU197E User Manual Download Page 16](http://html.mh-extra.com/html/texas-instruments/swru197e/swru197e_user-manual_1094536016.webp)
swru197e
16/23
8.2
Updating the firmware manually in SmartRF Flash Programmer
You can also update the firmware manually using SmartRF Flash Programmer. You can use this
method if you like to have full control of the firmware image to be programmed on the controller of the
debugger (i.e. programming custom firmware or old firmware revisions).
1.
Start SmartRF Flash Programmer and select the tab called “EB application (USB)”. This tab
will let you program compatible firmware on the CC Debugger (or evaluation boards) via the
USB interface (i.e. no external programming device required).
2. Disconnect the debugger from any target board, and connect it to the PC via the USB cable.
The debugger will appear in the list of connected devices. Chip type will be listed as N/A.
3. Select the flash image you want to program on the debugger. Normally, you would select:
C:\Program Files (x86)\Texas Instruments\SmartRF Tools\Firmware\CC
Debugger\cebal_fw_srf05dbg.hex
1
4.
Select the action “Erase, program and verify”
5.
Click the “Perform actions” buttons. The programming procedure will start. Note that this will
take several seconds.
6. The CC Debugger will reappear in the list of connected devices, now showing the new
firmware revision in the device list.
7. Done!
1
Assuming default installation path of SmartRF Flash Programmer.
1
1
2
4
5
3
Summary of Contents for SWRU197E
Page 1: ...CC Debugger User s Guide SWRU197E ...
Page 23: ......