MSP430FG4619, MSP430FG4618, MSP430FG4617, MSP430FG4616
MSP430CG4619, MSP430CG4618, MSP430CG4617, MSP430CG4616
www.ti.com
SLAS508J – APRIL 2006 – REVISED JUNE 2015
5.12
Wake-up Timing From LPM3
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
f = 1 MHz
6
t
d(LPM3)
Delay time
f = 2 MHz
V
CC
= 2.2 V, 3 V
6
µs
f = 3 MHz
6
5.13
RAM
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
VRAMh
CPU halted
(1)
1.6
V
(1)
This parameter defines the minimum supply voltage when the data in program memory RAM remain unchanged. No program execution
should take place during this supply voltage condition.
5.14
LCD_A
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
Charge pump enabled
V
CC(LCD)
Supply voltage
(1)
2.2
3.6
V
(LCDCPEN = 1, VLCDx > 0000)
V
LCD(typ)
= 3 V, LCDCPEN = 1,
I
CC(LCD)
Supply current
(1)
VLCDx= 1000, all segments on, f
LCD
= f
ACLK
/32,
2.2 V
3
µA
no LCD connected
(2)
, T
A
= 25°C
Charge pump enabled
C
LCD
Capacitor on LCDCAP
(3) (4)
4.7
µF
(LCDCPEN = 1, VLCDx > 0000)
f
LCD
LCD frequency
1.1
kHz
VLCDx = 0000
V
CC
VLCDx = 0001
2.60
VLCDx = 0010
2.66
VLCDx = 0011
2.72
VLCDx = 0100
2.78
VLCDx = 0101
2.84
VLCDx = 0110
2.90
VLCDx = 0111
2.96
V
LCD
LCD voltage
(4)
V
VLCDx = 1000
3.02
VLCDx = 1001
3.08
VLCDx = 1010
3.14
VLCDx = 1011
3.20
VLCDx = 1100
3.26
VLCDx = 1101
3.32
VLCDx = 1110
3.38
VLCDx = 1111
3.44
3.60
R
LCD
V
LCD
= 3 V, CPEN = 1,
LCD driver output impedance
2.2 V
10
k
Ω
VLCDx = 1000, I
LOAD
= ±10 µ
Α
(1)
Refer to the supply current specifications I
(LPM3)
for additional current specifications with the LCD_A module active.
(2)
Connecting an actual display increases the current consumption depending on the size of the LCD.
(3)
Enabling the internal charge pump with an external capacitor smaller than the minimum specified might damage the device.
(4)
Segments S0 through S3 are disabled when the LCD charge pump feature is enabled (LCDCPEN = 1) and, therefore, cannot be used
together with the LCD charge pump. On the MSP430xG461x devices only, S0 through S3 are also disabled if VLCDEXT = 1. This
setting is typically used to apply an external LCD voltage supply to the LCDCAP terminal. For these devices, set LCDCPEN = 0,
VLCDEXT = 0, and VLCDx > 0 to enable an external LCD voltage supply to be applied to the LCDCAP terminal.
Copyright © 2006–2015, Texas Instruments Incorporated
Specifications
21
Submit Documentation Feedback
Product Folder Links:
MSP430FG4619 MSP430FG4618 MSP430FG4617 MSP430FG4616 MSP430CG4619
MSP430CG4618 MSP430CG4617 MSP430CG4616