Device Information
Device Configuration
Telemetry Plotter
Device Telemetry
Display Options
Design Tool
Device Evaluation
5
SNVA481B – October 2011 – Revised January 2020
Copyright © 2011–2020, Texas Instruments Incorporated
AN-2143 LM5064 Evaluation Kit
The device should be detected on the PMBusand the initial load screen should appear as shown in
.
Figure 5. Initial GUI Screen
If a device is not detected, an option is provided to rescan, ignore, or exit the GUI. If the hardware is
intended to be connected, check the USB connection to the PCB, FTDI connection to the evaluation
module, and verify that the power is present on the evaluation PCB by measuring the voltage between the
GND1_s (+) and VEE_s (-) testpoints. Ignoring the detection message allows use of the integrated design
tool without the hardware connected.
Figure 6. LM5064 Block Level Representation
Double click on the detected device ID (NSC-LM5064-AA) to display a block level representation of the
device as shown in
. The block level view of the device provides a display of all the telemetry data
as well as most of the faults and warnings supported by the device. The faults and warnings supported
are generally associated with an invalid input or output condition.