0x21 DeviceName()
133
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
17.32 0x21 DeviceName()
This read-block function returns the assigned pack name stored in
Device Name
.
SBS
Cmd
Name
Access
Protocol
Type
Length in Bytes
Min
Max
Unit
SE
US
FA
0x21
DeviceName()
R
R
R
Block
String
7+1
—
—
ASCII
Class
Subclass
Name
Format
Length in Bytes
Min
Max
Default
Unit
SBS Configuration
Data
Device Name
String
8
—
—
bq78350-R1
ASCII
17.33 0x22 DeviceChemistry()
This read-block function returns the battery chemistry used in the pack stored in
Device Chemistry
.
SBS
Cmd
Name
Access
Protocol
Type
Length in Bytes
Min
Max
Unit
SE
US
FA
0x22
DeviceChemistry()
R
R
R
Block
String
4+1
—
—
ASCII
Class
Subclass
Name
Format
Length in Bytes
Min
Max
Default
Unit
SBS Configuration
Data
Device Chemistry
String
5
—
—
LION
ASCII
17.34 0x23 ManufacturerData()/CalibrationData()
This read-block function returns several elements of manufacturing-related pack information in the default
mode. It is also used to return a variety of other data and can provide measured voltage, current, and
temperature data for calibration purposes in CALIBRATION mode. See
ManufacturerAccess()
, for more details on these options.
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Unit
Note
SE
US
FA
0x23
ManufacturerData()
R
R
R
Block
S32+1
Status
Condition
Action
ManufacturerData
Valid command sent
Returns pack information on
ManufacturerData()
The default data returned by
ManufacturerData()
is stored in the following data flash.
Class
Subclass
Name
Format
Length in Bytes
Min
Max
Default
Unit
SBS Configuration
Data
Manufacturer Info
String
33
—
—
—
ASCII
When the bq78350-R1 is in CALIBRATION mode, this command changes the data it returns. See
for more details on the data and format.
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Unit
Note
SE
US
FA
0x23
CalibrationData()
R
R
R
Block
H2+S24