0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
117
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
PCHG_TEST (Bit 0)
: Precharge FET Test
1 = Precharge FET test activated
0 = Disabled
17.2.42 ManufacturerAccess() 0x0058 AFEStatus
This command returns the configuration of the companion AFE (address 0x00). See the AFE
bq769x0 3-
Series to 15-Series Cell Battery Monitor Family for Li-Ion and Phosphate Applications Data Manual
(
) for further details.
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x0058
R
AFEStatus
Hex
2
0x0000
0x00FF
—
—
17.2.43 ManufacturerAccess() 0x0059 AFEConfig
This command returns the configuration of the companion AFE (address 0x01 to 0x0B). See the AFE
bq769x0 3-Series to 15-Series Cell Battery Monitor Family for Li-Ion and Phosphate Applications Data
Manual
(
).
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x0059
R
AFEConfig
String
11+1
—
—
—
—
17.2.44 ManufacturerAccess() 0x005A AFEVCx
This command returns the cell voltage measurement data of the companion AFE (address 0x0C to 0x29)
on
ManufacturerBlockAccess()
or
ManufacturerData()
. See the AFE
bq769x0 3-Series to 15-Series Cell
Battery Monitor Family for Li-Ion and Phosphate Applications Data Manual
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x005A
R
AFEVCx
String
30+1
—
—
—
—
17.2.45 ManufacturerAccess() 0x005B AFEData
This command returns the system voltage, temperature, and current measurement data of the companion
AFE (address 0x2A to 0x33, 0x50, 0x51, and 0x59) on
ManufacturerBlockAccess()
or
ManufacturerData()
.
See the AFE
bq769x0 3-Series to 15-Series Cell Battery Monitor Family for Li-Ion and Phosphate
Applications Data Manual
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x005B
R
AFEData
String
13+1
—
—
—
—
17.2.46 ManufacturerAccess() 0x0060 Lifetime Data Block 1
This command returns the Lifetime data on
ManufacturerBlockAccess()
or
ManufacturerData()
. See for
details.
Status
Condition
Action
Activate
0x0060 to
ManufacturerAccess()
Outputs lifetime data values of Max Cell Voltage on
ManufacturerBlockAccess()
or
ManufacturerData()