153
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
Data Flash Summary
Table 19-1. Data Flash Summary Table (continued)
Class
Subclass
Address
Name
Type
Min Value
Max Value
Default
Units
PF Status
Device
Temperature
Data
0x4202
TS2 Temperature
I2
–32768
32767
0
0.1°K
PF Status
Device
Temperature
Data
0x4204
TS3 Temperature
I2
–32768
32767
0
0.1°K
PF Status
Device
Temperature
Data
0x4206
Gauge Internal
Temperature
I2
–32768
32767
0
0.1°K
PF Status
AFE Regs
0x4208
AFE SYS Stat
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x4209
AFE Cell Balance1
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420A
AFE Cell Balance2
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420B
AFE Cell Balance3
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420C
AFE Sys Control1
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420D
AFE Sys Control2
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420E
AFE Protection1
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x420F
AFE Protection2
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x4210
AFE Protection3
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x4211
AFE OV Trip
H1
0x0
0xFF
0x0
Hex
PF Status
AFE Regs
0x4212
AFE UV Trip
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4180
1st Status Status A
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4181
1st Status Status B
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4182
1st Safety Status C
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4184
1st Time to Next Event
U1
0
255
0
s
Black Box
Safety Status
0x4185
2nd Status Status A
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4186
2nd Status Status B
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4187
2nd Safety Status C
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x4189
2nd Time to Next Event
U1
0
255
0
s
Black Box
Safety Status
0x418A
3rd Status Status A
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x418B
3rd Status Status B
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x418C
3rd Safety Status C
H1
0x0
0xFF
0x0
Hex
Black Box
Safety Status
0x418E
3rd Time to Next Event
U1
0
255
0
s
Black Box
PF Status
0x418F
1st PF Status A
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4190
1st PF Status B
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4191
1st PF Status C
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4193
1st Time to Next Event
U1
0
255
0
s
Black Box
PF Status
0x4194
2nd PF Status A
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4195
2nd PF Status B
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4196
2nd PF Status C
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x4198
2nd Time to Next Event
U1
0
255
0
s
Black Box
PF Status
0x4199
3rd PF Status A
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x419A
3rd PF Status B
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x419B
3rd PF Status C
H1
0x0
0xFF
0x0
Hex
Black Box
PF Status
0x419D
3rd Time to Next Event
U1
0
255
0
s
System Data
Manufacturer
Data
0x4040
Manufacturer Info A
Length
U1
1
32
32
—
System Data
Manufacturer
Data
0x4041
Manufacturer Info Block
A01
H1
0x0
0xFF
0x61
Hex
System Data
Manufacturer
Data
0x4042
Manufacturer Info Block
A02
H1
0x0
0xFF
0x62
Hex
System Data
Manufacturer
Data
0x4043
Manufacturer Info Block
A03
H1
0x0
0xFF
0x63
Hex
System Data
Manufacturer
Data
0x4044
Manufacturer Info Block
A04
H1
0x0
0xFF
0x64
Hex