0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
107
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
Status
Condition
Action
Activate
0x0051 to
ManufacturerAccess()
Outputs
SafetyStatus()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
OC
RSVD
CTO
RSVD
PTO
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RSVD
OCDL
OTF
AFE_OV
RD
UTD
UTC
OTD
OTC
ASCDL
ASCD
AOLDL
AOLD
OCD
OCC
COV
CUV
RSVD (Bits 31–21)
: Reserved
OC (Bit 20)
: Overcharge
1 = Detected
0 = Not Detected
RSVD (Bit 19)
: Reserved
CTO (Bit 18)
: Charge Timeout
1 = Detected
0 = Not Detected
RSVD (Bit 17)
: Reserved
PTO (Bit 16)
: Precharge Timeout
1 = Detected
0 = Not Detected
RSVD (Bits 15)
: Reserved
OCDL (Bit 14)
: Overcurrent During Discharge Latch
1 = Detected
0 = Not Detected
OTF (Bit 13)
: Overtemperature Fault
1 = Detected
0 = Not Detected
AFE_OVRD (Bit 12)
: AFE Alert
1 = Detected
0 = Not Detected
UTD (Bit 11)
: Undertemperature During Discharge
1 = Detected
0 = Not Detected
UTC (Bit 10)
: Undertemperature During Charge
1 = Detected
0 = Not Detected
OTD (Bit 9)
: Overtemperature During Discharge
1 = Detected
0 = Not Detected
OTC (Bit 8)
: Overtemperature During Charge
1 = Detected